2.2 19“ System
SPECIFICATIONS
THQ 19” SYSTEM
Channels
Up to 3
High voltage
Up to 30 kV
Module compatibility
(1
CPS, DPS, EPS
(3
(combinable)
- wie 1 und 2 Kanal
voltage setting – local
turn potentiometer – V
SET
(local)
Resolution voltage setting – Remote
analog I/O with V
set
/V
mon
= 0 to 5 V (remote) or Interface
Resolution current setting – local
turn potentiometer – I
SET
(local)
Resolution current setting – Remote
analog I/O with V
set
/V
mon
= 0 to 5 V (“remote”) or Interface
4-digit Display
Interface (USB)
Resolution voltage measurement
V
out
< 1 kV
0,1 V
0,01 V
V
out
1 kV – 8 kV
1 V
0,1 V
V
out
> 10 kV
10 V
1 V
Resolution current measurement
4-digit Display
Interface (USB)
I
out
< 10 mA
1 µA
0,1 µA
I
out
10 mA – < 0,1 A
10 µA
1 µA
I
out
> 0,1 A
0,1 mA
10 µA
Measurement accuracy
The measurement accuracy is guaranteed in the range 1% • V
nom
< V
out
< V
nom
/ 1% • I
nom
< I
out
< I
nom
and for 1 year
Protection
(1
INHIBIT
Overload and short circuit protected
(
ATTENTION: there is only one short circuit or arc per second allowed!)
HV connector
CPS
0 – 7 kV:
SHV
≥ 10 kV:
L16
≥ 20 kV:
L30
DPS
SHV
EPS (60W)
0 – 7 kV:
SHV
≥ 10 kV:
L16
≥ 20 kV:
L30
Rated AC mains input
100 – 264 VAC with PFC
Input power
75 W
100 W
200 W
Fuse
5x20mm 2.0A, inert
5x20mm 4.0A, inert
AC power connector
IEC 60320-C14, Figure 23
Connection
AIO
(2
USB Figure 19
THQ Systems - CONFIGURABLE AC/DC LABORATORY HV SUPPLY | Last modified on: 2022-04-21 | www.iseg-hv.com
11/41