Safety instructions
Following instructions are made for the personal safety of the operator, the safe use of this product and the connected devices.
Warning!
Before operations at the load or the high voltage output of the power supply are started, the device
has to be switched off, the discharge of residual voltage has to be finished and the high voltage
output of the power supply must be properly grounded.
Depending on application residiual voltages
can be present for long time periods. These residiual voltages can lead to severe injuries.
This High Voltage Power Supply has to be installed by trained and qualified personnel only.
Warning!
High voltage power supplies of the device class HPS 300 W, 800 W are supplied from single phase
mains voltage and generate an output voltage up to 30 kV. The disregard of this voltage condition
can cause death, heavy injuries or material damage.
Before connecting to the local mains it must be made sure that the nominal line voltage of this unit matches to the local mains.
The power input has to be fused (see technical data).
After system assembly the connections with the protective ground have to be checked for proper connection!
Warning!
For devices equipped with a LEMO-HV connector, the high voltage must not be switched on until the
corresponding counterpart has been contacted.
The HV cable has to be connected to the load properly and isolated according to proof-voltage.
The shield of the HV cable is always connected to the housing. It can be used as return.
The factory installed short-circuit bridge must be mounted between the connections "0V" and "X". If this short-circuit bridge is
not installed, an additional conductor with a cross-section of at least 1.5 mm² must be used as the return conductor. This
conductor must be connected to the "0V" connection. The "0V" terminal can accept a voltage related to the earth potential.
Warning!
The user has to ensure that no danger will occur because of the voltage between the return
conductor and the protective ground!
A specified air flow rate (see technical details) has to be guaranteed under any circumstances. Therefore do not cover any
air input or output slots.
If the device is used as a desk top instrument, the enclosed distance pieces have to be installed at the bottom side of the
device.