By pressing the rotary encoder VOLTAGE or CURRENT in HV ON state, the corresponding set value is displayed for a short
time to allow exact adjustment.
If the set values aren’t changed, the device shows the measured values again after four seconds. By pressing the correspond-
ing rotary encoder again, this delay can be shortened.
After turning high voltage off, the displays show the measured values while ramping down. After four seconds with a measured
voltage lower than 60 V, the device shows the set values again.
5.2.2
Menu
In HV-OFF mode the device menu is activated by pressing the button MENU.
If no button is pressed, the display switch back to HV-OFF mode after 30 seconds. The menu can also be closed without
changing any value by pressing the button ESC.
By turning the rotary encoder VOLTAGE you can scroll through the menu. By pressing the rotary en-coder VOLTAGE the
displayed menu point is selected. The setting can be changed by the active rotary encoder (shown by yellow LED). By pressing
the active rotary encoder the changes are stored and the main menu is displayed again.