iES6 Series User’s Manual
iS5 Communications Inc.
41
Label
Description
Context Table
Configure SNMP v3 context table. Assign the context name of context
table. Click "Apply" to change context name
User Table
1. Configure SNMP v3 user table.
2.
User ID:
set up the user name.
3.
Authentication Password:
set up the
authentication password.
4.
Privacy Password:
set up the private password.
5. Click "Add" to add context name.
6. Click "Remove" to remove unwanted context name.
Group Table
1. Configure SNMP v3 group table.
2.
Security Name (User ID):
assign the user name
that you have set up in user table.
3.
Group Name:
set up the group name.
4. Click "Add" to add context name.
5. Click "Remove" to remove unwanted context name.
Access Table
1. Configure SNMP v3 access table.
2.
Context Prefix:
set up the context name.
3.
Group Name:
set up the group.
4.
Security Level:
select the access level.
5.
Context Match Rule:
select the context match rule.
6.
Read View Name:
set up the read view.
7.
Write View Name:
set up the write view.
8.
Notify View Name:
set up the notify view.
9. Click "Add" to add context name.
10. Click "Remove" to remove unwanted context name.
MIBview Table
1. Configure MIB view table.
2.
ViewName:
set up the name.
3.
Sub-Oid Tree:
fill the Sub OID.
4.
Type:
select the type – exclude or included.
5. Click "Add" to add context name.
6. Click "Remove" to remove unwanted context name.
5.1.10
System Warning
The Warning function is very important for managing a switch. The switch can be managed using
SYSLOG, E-MAIL, and Fault Relay. This can help to monitor the switch status on remote sites. When
an event occurs, the warning message gets sent to an appointed server, E-MAIL, or relay fault on a switch
panel.