iES28TG/iES28GF User Manual
181
iS5 Communications Inc.
PTP Clock Configurations
Label
Description
Delete
Check this box and click
Save
to delete the clock instance
Clock Instance
Indicates the instance of a particular clock instance [0..3]
Click on the clock instance number to edit the clock details
Device Type
Indicates the type of the clock instance. There are five device types.
Ord-Bound
: ordinary/boundary clock
P2p Transp
: peer-to-peer transparent clock
E2e
Transp
: end-to-end transparent clock
Master Only
: master only
Slave Only
: slave only
Port List
Set check mark for each port configured for this Clock Instance.
2 Step Flag
Static member defined by the system;
true
if two-step Sync
events and Pdelay_Resp events are used
Clock Identity
Shows a unique clock identifier
One Way
If
true,
one-way measurements are used. This parameter applies only
to a slave. In one-way mode no delay measurements are
performed, i.e. this is applicable only if frequency synchronization
is needed. The master always responds to delay requests.