EAPOL Counters
These supplicant frame counters are available for the following administrative states:
• Force Authorized
• Force Unauthorized
• 802.1X
Rx/Tx Name
IEEE Name
Description
Rx
Total
dot1xAuthEapolFramesRx
The number of valid EAPOL frames of any type that
have been received by the switch.
Rx
Response ID
dot1xAuthEapolRespIdFra
mesRx
The number of valid EAPOL Response Identity
frames that have been received by the switch.
Rx
Responses
dot1xAuthEapolRespFram
esRx
The number of valid EAPOL response frames (other
than Response Identity frames) that have been
received by the switch.
Rx
Start
dot1xAuthEapolStartFram
esRx
The number of EAPOL Start frames that have been
received by the switch.
Rx
Logoff
dot1xAuthEapolLogoffFra
mesRx
The number of valid EAPOL Logoff frames that have
been received by the switch.
Rx
Invalid Type
dot1xAuthInvalidEapolFra
mesRx
The number of EAPOL frames that have been
received by the switch in which the frame type is
not recognized.
Rx
Invalid Length
dot1xAuthEapLengthErro
rFramesRx
The number of EAPOL frames that have been
received by the switch in which the Packet Body
Length field is invalid.
Tx
Total
dot1xAuthEapolFramesTx
The number of EAPOL frames of any type that have
been transmitted by the switch.
Tx
Request ID
dot1xAuthEapolReqIdFra
mesTx
The number of EAPOL Request Identity frames that
have been transmitted by the switch.
Tx
Requests
dot1xAuthEapolReqFram
esTx
The number of valid EAPOL Request frames (other
than Request Identity frames) that have been
transmitted by the switch.