background image

DMM

4880 & DMX

4880 Instruction Book 

Revision 0

 

www.irtelectronics.com 

Page 6 of 16 

4880

DMM_4880

DMX_ib_Rev0.doc 

Technical Specifications 

 

DMM

4880: 

Inputs: 

Type 1 

4 x STM

1 (OC

3), 75

Ω

, 1Vp

p, BNC connector. 

Electrical Characteristics 

CMI encoded. 

Data Rate 

155.52 Mb/s. 

Equalisation 

Automatic, > 200m at 155Mb/s for Belden 8281 or equivalent cable. 

 
Type 2 (Optional) 

1 x optical STM

4 (OC

12), LC/PC (standard) optical connector. 

Optical Characteristics 

NRZ encoded. 

Data Rate 

622.08 Mb/s. 

 

Output: 

Type 

1 x optical STM

4 (OC

12), SC/PC (standard) optical connector

1

Optical Characteristics 

NRZ encoded. 

Data Rate 

622.08 Mb/s. 

 

Alarm Output: 

MAJOR 

Not used. Open circuit on loss of power. 

 

MINOR 

Open circuit on no valid input STM

1 streams present, or loss of power. 

 

DMX

4880: 

Input: 

Type 

1 x STM

4 (OC

12), optical, SC/PC optical connector (standard). 

Optical Characteristics 

NRZ encoded. 

Data Rate 

622.08 Mb/s. 

 

Outputs: 

Type 

4 x STM

1 (OC

3) 75

Ω

, 1Vp

p, BNC connector. 

Data Rate 

155.52 Mb/s. 

 

Alarm Output:

 

MAJOR 

Open circuit on no valid STM

4 input present, or loss of power. 

 

MINOR 

Open circuit on no valid output STM

1 streams present, or loss of power. 

 

Optical 

Optical path loss

2

 

3 to 18 dB with PIN detector (typically 20dB), 

Optical fibre 

Designed for use with 9/125 

μ

m single mode fibre. 

Optical wavelength 

1310nm (DFB laser 

 standard). 

Optical connectors 

SC/PC (standard). 

DMM

4880 optical output 

0 dBm +3/

0 dB standard DFB laser, 

DMX

4880

 

optical input 

PIN detector, 

3 to 

18 dBm input level 

 

Power Requirements

 

28 Vac CT (14

0

14) or 

±

16 Vdc. 

Power consumption 

7 VA. 

 

Other 

Temperature range 

 50° C ambient. 

Mechanical 

Suitable for mounting in IRT 19" rack chassis with input, output and power 
connections on the rear panel. 

Finish 

Front panel 

Grey background, black lettering & red IRT logo. 

 Rear 

assembly 

Detachable 

silk

screened PCB with direct mount connectors to Eurocard and 

external signals. 

Dimensions 

6 HP x 3 U x 220 mm IRT Eurocard. 

 
 

NOTE:

  1 

If optional STM

4 reference fitted, standard output optical connector is an 

LC/PC type. 

 

 

2

 

Optical attenuator required for optical paths <3dB optical loss. 

 

Due to our policy of continuing development, these specifications are subject to change without notice. 

IRT 

Communications 

www.irtcommunications.com

Summary of Contents for DMM-4880

Page 1: ...p www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Phone 02 9439 3744 Fax 02 9439 7439 International 61 2 9439 3744 61 2 94...

Page 2: ...IRT Eurocard Type DMM 4880 DMX 4880 4 STM 1 to STM 4 Multiplexer De Multiplexer Revision History Revision Date By Change Description Applicable to 0 13 08 2010 AL Original Issue Firmware versions DMM4...

Page 3: ...Description 5 Technical Specifications 6 Configuration 7 Installation 8 Signal Connections 8 DMM 4880 8 DMX 4880 10 Front Panel LEDs 11 DMM 4880 11 DMX 4880 11 Front and rear layouts 12 Operation 13...

Page 4: ...adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for removing covers or use of extender cards Optical Safety The l...

Page 5: ...k into the original four 155Mb s STM 1 signals Front panel indications on the DMX 4880 de multiplexer shows if valid encoded STM 1 signals are present SNMP Simple Network Management Protocol is availa...

Page 6: ...or loss of power MINOR Open circuit on no valid output STM 1 streams present or loss of power Optical Optical path loss2 3 to 18 dB with PIN detector typically 20dB Optical fibre Designed for use wit...

Page 7: ...0 card and the CDM card SNMP Agent of the frame major and minor SNMP alarms that are reported to the CDM card of the frame can be disabled DMX 4880 SW1 1 Not used SW1 2 Not used SW1 3 Not used SW1 4 N...

Page 8: ...terminated in 75 Input cable equalisation is automatic for up to 200m of high quality 75 coaxial cable Belden 8281 or equivalent No adjustments are required STM 4 Reference Input The STM 4 reference...

Page 9: ...SK 7 IN4 PL4 SK10 SK 2 IN3 PL3 SK 11 IN2 SK 6 IN1 1 2 3 1 GND 2 MINOR 3 MAJOR STM 1 I P4 STM 1 I P1 STM 1 I P3 ALARM O P STM 1 I P2 DMM 4880 Rear Assembly Connections With STM 4 Ref I P option STM 4...

Page 10: ...nt to the corresponding STM 1 electrical input on the matching DMM 4880 Alarm Outputs Two relay alarm output states are provided via a phoenix style 3 pin plug Pin 3 is designated as Major pin 2 is de...

Page 11: ...put signal to synchronize with Only valid for DMM 4880 fitted with optional STM 4 reference input port The ALARM LED does not illuminate as there is no Major Alarm associated with the DMM 4880 DMX 488...

Page 12: ...ale and are intended to show connection order and approximate layout only I P 1 I P 2 I P 4 I P 3 ALARM REF I P DC DMM 488 0 N140 O P 1 O P 2 O P 4 O P 3 ALARM DC DMX 488 0 N140 SK 9 OUT3 PL4 SK10 SK...

Page 13: ...information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control commands for the managed devic...

Page 14: ...tible need a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters such as alarm states inputs and...

Page 15: ...the Urgent and Non Urgent alarms noAlarms 1 UrgentAlarms 2 no or invalid STM 4 input signal present nonUrgentAlarms 3 no valid STM 1 signals encoded on any channel All STM 1 signals are AIS An indica...

Page 16: ...ed by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment If pos...

Reviews: