4 Input: 

The optical STM

4 input port on the rear of the unit is an SC/PC (standard) optical connector for use with single 

mode fibre. 
 
The standard optical detector used is a PIN detector and is rated for an optical input between 

3dBm and 

18dBm. 

If the input signal strength is greater than 

3dBm an optical attenuator (5 or 10 dB recommended) must be used to 

avoid overdriving the detector. 
 

STM

1 Outputs: 

Four STM

1 electrical outputs are provided as 75

Ω

 output BNC connectors. Each STM

1 output is equivalent to the 

corresponding STM

1 electrical input on the matching DMM

4880. 

 

Alarm Outputs: 

Two relay alarm output states are provided via a phoenix style 3

pin plug. Pin 3 is designated as Major, pin 2 is 

designated as Minor, and pin 1 is ground. Both alarms are referenced to ground. 

 

Alarm conditions are as follows: 

Major  switch to Open Circuit on no valid STM

4 input present; 

Minor  switch to Open Circuit on no valid output STM

1 streams present, or 

 

no valid STM

4 input present. 

 

Both Major and Minor alarms switch to Open Circuit on power failure. 

 

 
 
 

 
 
 
 
 
 
 

1               GND

 

2               MINOR

 

3               MAJOR

STM-1 O/P 3 

ALARM O/P

DMX-4880 

Rear Assembly Connections

 

STM-4 I/P

STM-1 O/P 2

SK 9     OUT3

PL4

 

SK10 

SK 4     OUT4

SK 8     OUT1

SK3      OUT2

PL3

 

1

2

3

1-GND 
2-MINOR 
3–MAJOR

STM-1 O/P 1 

STM-1 O/P 4

IRT 

Communications 

www.irtcommunications.com

Summary of Contents for DMM-4880

Page 1: ...p www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Phone 02 9439 3744 Fax 02 9439 7439 International 61 2 9439 3744 61 2 94...

Page 2: ...IRT Eurocard Type DMM 4880 DMX 4880 4 STM 1 to STM 4 Multiplexer De Multiplexer Revision History Revision Date By Change Description Applicable to 0 13 08 2010 AL Original Issue Firmware versions DMM4...

Page 3: ...Description 5 Technical Specifications 6 Configuration 7 Installation 8 Signal Connections 8 DMM 4880 8 DMX 4880 10 Front Panel LEDs 11 DMM 4880 11 DMX 4880 11 Front and rear layouts 12 Operation 13...

Page 4: ...adjustments should only be made by suitably qualified personnel All operational adjustments are available externally without the need for removing covers or use of extender cards Optical Safety The l...

Page 5: ...k into the original four 155Mb s STM 1 signals Front panel indications on the DMX 4880 de multiplexer shows if valid encoded STM 1 signals are present SNMP Simple Network Management Protocol is availa...

Page 6: ...or loss of power MINOR Open circuit on no valid output STM 1 streams present or loss of power Optical Optical path loss2 3 to 18 dB with PIN detector typically 20dB Optical fibre Designed for use wit...

Page 7: ...0 card and the CDM card SNMP Agent of the frame major and minor SNMP alarms that are reported to the CDM card of the frame can be disabled DMX 4880 SW1 1 Not used SW1 2 Not used SW1 3 Not used SW1 4 N...

Page 8: ...terminated in 75 Input cable equalisation is automatic for up to 200m of high quality 75 coaxial cable Belden 8281 or equivalent No adjustments are required STM 4 Reference Input The STM 4 reference...

Page 9: ...SK 7 IN4 PL4 SK10 SK 2 IN3 PL3 SK 11 IN2 SK 6 IN1 1 2 3 1 GND 2 MINOR 3 MAJOR STM 1 I P4 STM 1 I P1 STM 1 I P3 ALARM O P STM 1 I P2 DMM 4880 Rear Assembly Connections With STM 4 Ref I P option STM 4...

Page 10: ...nt to the corresponding STM 1 electrical input on the matching DMM 4880 Alarm Outputs Two relay alarm output states are provided via a phoenix style 3 pin plug Pin 3 is designated as Major pin 2 is de...

Page 11: ...put signal to synchronize with Only valid for DMM 4880 fitted with optional STM 4 reference input port The ALARM LED does not illuminate as there is no Major Alarm associated with the DMM 4880 DMX 488...

Page 12: ...ale and are intended to show connection order and approximate layout only I P 1 I P 2 I P 4 I P 3 ALARM REF I P DC DMM 488 0 N140 O P 1 O P 2 O P 4 O P 3 ALARM DC DMX 488 0 N140 SK 9 OUT3 PL4 SK10 SK...

Page 13: ...information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control commands for the managed devic...

Page 14: ...tible need a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters such as alarm states inputs and...

Page 15: ...the Urgent and Non Urgent alarms noAlarms 1 UrgentAlarms 2 no or invalid STM 4 input signal present nonUrgentAlarms 3 no valid STM 1 signals encoded on any channel All STM 1 signals are AIS An indica...

Page 16: ...ed by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment If pos...

Reviews: