FRONT DOOR PARTS LIST

Item # Cat. No

Description

1

H5639 Door Rope Kit, 7/8” Dia. (6’ 2”)

2

H5629 Upper Hinge Pin

3

H5625 Upper Hinge Pin E-Clip

4

H5628 Lower Hinge Pin

6

H5640 Glass Gasket Kit (8’ 4”)

7

H5577 Set of 6 screws and 6 washers for door assembly

8

H5654 Spring Handle / Nickel

9

71067 Traditional Door Glass / Plain

10

71057 Traditional Door Faceplate / Black
71059 Traditional Door Faceplate / Nickel
71145 Traditional Door Faceplate / Brushed Nickel

11

71072 Arch Door Glass / Plain

12

71060 Arch Door Faceplate / Black
71062 Arch Door Faceplate / Nickel
71144 Arch Door Faceplate / Brushed Nickel

13

H5579 Traditional Door Back w/ Handle (door gasket included)

14

H5578 Arch Door Back w/ Handle (door gasket included)

ASH DRAWER PEDESTAL AND PEDESTAL

15

H5514 Small & Large Pedestal Rear Block Off Plate w/ Hole

16

H5557 Ash Drawer for Small Pedestal

17

H5564 Ash Plug Remover and Rake

18

H5516 Aluminum Flex Tubing Kit w/ clamp (15” of 4” dia.)

19

H5565 6” x 6-1/2” Rodent Screen

LEGS AND LEG PARTS

18

H5516 Aluminum Flex Tubing Kit w/ clamp (15” of 4” dia.)

20

H5558 Single Black Cascade Leg

21

H5669 Single Black Olympic Leg
H5621 Single Nickel Olympic Leg

H5619

Single Brushed Nickel Olympic Leg

22

H5649

Heatshield / Leg Fastener Kit

23

71110

Bottom Heatshield / S160 and SA160

24

H5662

Cascade / Olympic Leg Kit Outside Air Plenum Box

FSB BLOWER PARTS

25

H8062

FSB700 Blower Only Assembly w/ blower wiring harness

26

H5658

Fan Blade (FSB700)

27

H5657

Fan Cage (FSB700)

28

H8063

FSB700 Blower Only Wire Harness

29

H8064

Snap Switch w/gasket and screws

30

H5742

Speed Control - High Temperature (FSB700)

31

H8065

Control Panel Assembly w/ Snap Switch Housing As-

sembly

32

H8066

Control Switch (Manual, Off, Automatic)

S160 AND SA160 STOVE PARTS

33

H5627

Removable Inner Flue Collar Ring

34

F1871

IronStrike

®

 Nameplate Kit w/ Hardware - Nickel 

35

H5650

Draft Rod Knob

36

H8081

Ash Block Off - Hearthplate

37

H5661

Cast Iron Ash Plug

38

H5582

1/2 Cut Brick for Ash Removal

39

H5612

Firebrick 4-1/2” x 9” (10 per stove)

40

H5576

Firebrick 4-1/4” x 9” (2 per stove)

41

H5607

Firebrick 2-1/4” x 9” (3 per stove)

42

H3095

Firebrick 2-1/4” x 8-7/8” (1 per stove)

43

H5604

Firebrick 1-1/2” x 9” (1 per stove)

44

H5597

Firebrick 1-1/2” x 8-7/8” (1 per stove)

45

H3104

Front Baffle/Secondary Burn Tube Assembly

46

H3105

Middle/Rear Baffle/Secondary Burn Tube Assembly

47

H3103

Complete Baffle/Secondary Burn Tube Assembly (in-

cludes tubes and all mounting hardware) 

48

H8017

Baffle Blanket 20” x 11” x 1” 

49

H8016

Baffle Board Kit w/ Baffle Blanket

MISCELLANEOUS PARTS

71052

Dry Graphite (Apply to door handle and door hinges)

H5633

Anti Seize 2 gram pouch

REPLACEMENT PARTS - MODELS S160 AND SA160

Contact an IHP dealer to obtain any of these parts. Never use 

substitute materials. Use of non-approved parts can result in 

poor performance and safety hazards.

Summary of Contents for Striker S160

Page 1: ...18 A French manual is available upon request Order P N 900127 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 900127 00 This appliance must be...

Page 2: ...for Installation 7 Installation Clearances 8 Typical Installation Figures 9 Chimney Installation 10 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Plea...

Page 3: ...g season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a...

Page 4: ...he actual vertical vent height to determine your effective draw In this case if you had 14 feet of vertical vent the effective draw would only be approximately 9 feet 14 ft 5 ft 9 ft therefore it may...

Page 5: ...a steel container with a tight fitting lid and moved outdoors immediately Other waste shall not be placed in this container The closed container of ashes should be placed on a non combustible floor o...

Page 6: ...THE AMOUNT OF AIR ENTERING THE STOVE IMMEDIATELY BURN IN PERIOD PAINT CURING 4 4 8 Standard Cord of Wood 8 Ft 2 4M 4 Ft 1 2M 4 Ft 1 2M Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page...

Page 7: ...Shield attaches to rear of stove pipe and must run from stove top to ceiling Pipe shield shall be UL listed Residential chimney systems must be from the same brands as listed for mobile homes but conn...

Page 8: ...m 72 1829mm USA 8 200mm from door opening Canada 8 200mm from sides and back of unit u Dimensions to Stove Body v Clearances may only be reduced by means approved by the regulatory authority Mobile Ho...

Page 9: ...ure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not...

Page 10: ...nted to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted into a thimble the joint must be tight enough so that it will not be dislod...

Page 11: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Page 12: ...the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves during installation in case of...

Page 13: ...the floor if so desired Slip the flexible outside air tube through the hole in the floor leaving 1 of tube above the floor protector surface using tape to hold it in place 6 Place the stove on the fl...

Page 14: ...pper wire or equivalent 11 Install bricks as per instructions on Pages 15 and 16 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blanket can be...

Page 15: ...he baffle boards so as not to block exhaust flow to the flue Use a ruler or a piece of kindling to reach over the baffle blanket to be sure it is completely flat on top of the baffle boards Measure br...

Page 16: ...the front to rear of the firebox Start by setting the back side of the board on the rear baffle making sure that it is placed far enough back to lift up and onto the front baffle Next you will place...

Page 17: ...l tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor...

Page 18: ...ot enough to effectively heat the air moved by the blower If the air coming from the blower feels cool one should either decrease the blower speed or stoke the fire to build up more heat NOTE Turn blo...

Page 19: ...d the appliance let the appliance top cool down to 275 to 400 degrees on Elites locatethermometeronthefaceoftheinsertjustabovethedoor Now load the firebox and set the draft control At this point you m...

Page 20: ...pected at least once a year by a qualified service technician to ensure gaskets air tubes baffles and venting are in good repair to ensure proper performance Have degraded items replaced by a qualifie...

Page 21: ...r burns more build up Higher burns less build up Keep freshly loaded wood away from the glass After reloading allow all the wood to catch flame before dampering down the appliance GLASS REPLACEMENT IN...

Page 22: ...20 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffle b...

Page 23: ...nts in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these...

Page 24: ...tside Air Plenum Box FSB BLOWER PARTS 25 H8062 FSB700 Blower Only Assembly w blower wiring harness 26 H5658 Fan Blade FSB700 27 H5657 Fan Cage FSB700 28 H8063 FSB700 Blower Only Wire Harness 29 H8064...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 25 REPLACEMENT PARTS MODELS S160 AND SA160...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 Door Parts Blower Parts 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 25 29 31 28 27 26 32 30...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 22 24 18 20 21 23 Leg and Leg Parts...

Page 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal...

Page 29: ...pic Sculptured Nickel 4 per pkg 70008 LEG OLY BRN Olympic Sculptured Brushed Nickel 4 per pkg 70003 LEG CAS B Cascade Steel Black 4 per pkg HEAT SHIELD REQUIRED WITH LEGS 71110 WSHS 160 Heat Shield re...

Page 30: ...ctured By INNOVATIVE HEARTH PRODUCTS 1502 14th St NW Auburn WA 98001 USA PREVENT HOUSE FIRES Install and use only in accordance with manufacturer s installation and operating instructions and your loc...

Page 31: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Page 32: ...he Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions c...