NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Termination Cap 

with Spark Arrestor

Remove, if mobile 

home is transported

Storm 

Collar

Flashing

Support

Box

DVL Close 

Clearance 

Connector Pipe

Floor

Protector

3 Feet

Minimum

7 Feet 

Minimum

Double Wall Pipe

Using 6” Diameter Type L-Vent Connector Pipe

Mobile (Manufactured) Home Installation Shown

Figure 7 - Typical Installation

Minimum of 

12-15’ of Flue 

to achieve a 

stable draft.

Fasten each stove pipe 

connection with at least 

3 sheet metal screws.

Mobile home installations 

require a spark arrestor at the 

chimney termination.

All mobile home installa-

tions require an outside 

air kit (see 

Page 29

 for 

ordering information) 

and the stove must be 

secured to the floor and 

grounded to the mobile 

home chassis.

Install Outside Air 

Kits per instructions 

on 

Page 12

INSTALL VENTING SYSTEM PER VENT MANUFACTURERS 
INSTRUCTIONS!

Fasten stove pipe to 

flue collar using 3 

sheet metal screws.

Secure Stove

to floor

Grounded to Steel Chassis 

using a #8 AGW copper 

wire or equivalent.

Chassis

Floor

CHIMNEY INSTALLATION

•  Install chimney as per manufacturer’s instructions. Some brands of 

pipe may require removal of the spacer ring in the flue collar.

•  All horizontal runs of pipe should be as short as possible and are 

required by NFPA No. 211 to have an upward pitch or rise in the same 

direction the smoke travels of no less than 1/4” to the linear foot. The 

connector pipe must meet minimum clearances in any direction to 

walls or other combustible materials. It must attach to a listed double 

wall metal chimney at least 6” in diameter or to a masonry chimney 

with a flue passage of at least 48 square inches.

•  It is required that a chimney connector pipe not extend further than 

the inner wall of the flue when it is connected to a masonry chimney 

and that it either be cemented to the masonry or be installed without 

cement in a thimble connected to the masonry wall. When the 

connector is inserted into a thimble, the joint must be tight enough 

so that it will not be dislodged in normal use. Install connector at 

no less than the minimum clearances from the ceiling when using a 

90-degree elbow to pass through combustible constructions.

•  Chimney connector pipes should never pass through a floor, ceiling, 

fire wall, partition, or combustible construction of any type unless 

certain precautions are taken. The best method is to use a listed 

thimble and a listed chimney in accordance with the manufacturer’s 

directions. NFPA No. 211 gives approved methods for passing a flue 

pipe through combustible constructions (see Page 11).

Manufactured Home Installations

(ref. Figure 7)

This appliance is approved for installation into a manufactured 

(mobile) home in the USA ONLY!

Installation should be in accordance with the Mobile Home 

Construction and Safety Standard, Title 24 CFR, Part 3280 (in 

Canada CAN/CSA Z240 MH), or, when such a standard is not 

applicable, the Standard for Mobile Home Installations, ANSI 

A225.1.

All mobile home installations require an outside air kit (see Page 29 

for ordering information). The stove must be secured to the floor and 

grounded to the chassis of the mobile home.

WARNING:  DO NOT INSTALL IN SLEEPING ROOM OF A MOBILE 

HOME.

CAUTION:  THE STRUCTURAL INTEGRITY OF THE MOBILE HOME 

FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.

Approved Chimney - 

Your stove is approved for use with Class A, UL 

103 HT (U.S.) / ULC-S629 (Canada) Listed Residential Type and Building 

Heating Appliance Chimney (HT chimney - 2100° Fahrenheit) and double 

wall connector pipe

.  

Approved chimney brands are Security Chimneys™,

 

Jakes Evans/GSW, Dura-vent, Metal Fab, Ameri-Tec, Metalbestos and 

Industrial Chimney (ICC).

Clearances to connector shall be measured from 6” flue collar. Restric-

tions apply! Read instructions before installing.

YOUR CHIMNEY INSTALLATION MUST COMPLY WITH LOCAL 

BUILDING AND FIRE CODES.

Stove

Side View

Summary of Contents for Striker S160

Page 1: ...18 A French manual is available upon request Order P N 900127 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 900127 00 This appliance must be...

Page 2: ...for Installation 7 Installation Clearances 8 Typical Installation Figures 9 Chimney Installation 10 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Plea...

Page 3: ...g season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a...

Page 4: ...he actual vertical vent height to determine your effective draw In this case if you had 14 feet of vertical vent the effective draw would only be approximately 9 feet 14 ft 5 ft 9 ft therefore it may...

Page 5: ...a steel container with a tight fitting lid and moved outdoors immediately Other waste shall not be placed in this container The closed container of ashes should be placed on a non combustible floor o...

Page 6: ...THE AMOUNT OF AIR ENTERING THE STOVE IMMEDIATELY BURN IN PERIOD PAINT CURING 4 4 8 Standard Cord of Wood 8 Ft 2 4M 4 Ft 1 2M 4 Ft 1 2M Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page...

Page 7: ...Shield attaches to rear of stove pipe and must run from stove top to ceiling Pipe shield shall be UL listed Residential chimney systems must be from the same brands as listed for mobile homes but conn...

Page 8: ...m 72 1829mm USA 8 200mm from door opening Canada 8 200mm from sides and back of unit u Dimensions to Stove Body v Clearances may only be reduced by means approved by the regulatory authority Mobile Ho...

Page 9: ...ure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not...

Page 10: ...nted to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted into a thimble the joint must be tight enough so that it will not be dislod...

Page 11: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Page 12: ...the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves during installation in case of...

Page 13: ...the floor if so desired Slip the flexible outside air tube through the hole in the floor leaving 1 of tube above the floor protector surface using tape to hold it in place 6 Place the stove on the fl...

Page 14: ...pper wire or equivalent 11 Install bricks as per instructions on Pages 15 and 16 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blanket can be...

Page 15: ...he baffle boards so as not to block exhaust flow to the flue Use a ruler or a piece of kindling to reach over the baffle blanket to be sure it is completely flat on top of the baffle boards Measure br...

Page 16: ...the front to rear of the firebox Start by setting the back side of the board on the rear baffle making sure that it is placed far enough back to lift up and onto the front baffle Next you will place...

Page 17: ...l tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor...

Page 18: ...ot enough to effectively heat the air moved by the blower If the air coming from the blower feels cool one should either decrease the blower speed or stoke the fire to build up more heat NOTE Turn blo...

Page 19: ...d the appliance let the appliance top cool down to 275 to 400 degrees on Elites locatethermometeronthefaceoftheinsertjustabovethedoor Now load the firebox and set the draft control At this point you m...

Page 20: ...pected at least once a year by a qualified service technician to ensure gaskets air tubes baffles and venting are in good repair to ensure proper performance Have degraded items replaced by a qualifie...

Page 21: ...r burns more build up Higher burns less build up Keep freshly loaded wood away from the glass After reloading allow all the wood to catch flame before dampering down the appliance GLASS REPLACEMENT IN...

Page 22: ...20 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffle b...

Page 23: ...nts in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these...

Page 24: ...tside Air Plenum Box FSB BLOWER PARTS 25 H8062 FSB700 Blower Only Assembly w blower wiring harness 26 H5658 Fan Blade FSB700 27 H5657 Fan Cage FSB700 28 H8063 FSB700 Blower Only Wire Harness 29 H8064...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 25 REPLACEMENT PARTS MODELS S160 AND SA160...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 Door Parts Blower Parts 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 25 29 31 28 27 26 32 30...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 22 24 18 20 21 23 Leg and Leg Parts...

Page 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal...

Page 29: ...pic Sculptured Nickel 4 per pkg 70008 LEG OLY BRN Olympic Sculptured Brushed Nickel 4 per pkg 70003 LEG CAS B Cascade Steel Black 4 per pkg HEAT SHIELD REQUIRED WITH LEGS 71110 WSHS 160 Heat Shield re...

Page 30: ...ctured By INNOVATIVE HEARTH PRODUCTS 1502 14th St NW Auburn WA 98001 USA PREVENT HOUSE FIRES Install and use only in accordance with manufacturer s installation and operating instructions and your loc...

Page 31: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Page 32: ...he Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions c...

Reviews: