background image

1.

 

OVERVIEW

Z-395 EHT

 electronic lock is a contactless reader combined with a standalone controller and 

electromechanical lock. The lock is powered by four AA type batteries. Compact, with five 
operational modes, easy in installation, programming and servicing, this lock is a perfect access 
control solution for various storage places: gym lockers, changing cabins, office furniture, trade 
equipment. Particularly broad application of these locks happens in places like SPA, water 
parks, gyms, swimming pools.

Z-395

 

EHT

 lock can be installed as a standalone device, or as a part of a complex access 

control solution. For access keys, it accepts contactless key fobs and bracelets. Z-395 EHT can 
operate in five different modes:
  - 

Gym Mode

keys are not tied to locks. Any key can open and close any free locker.

  - 

Logic Mode

:

 keys are not tied to locks. Any key can open and close any free locker. The 

number of used locker and battery levels are stored into keys. This is convenient when the user

 

forgets which locker he used. Can set the maximum for the number of lockers per one user 
(range 1 to 15). Computerized logging and lock setup. Only works with Lock Manager

 

software.

  - 

General Mode

:

 a typical lock controller operation: only the key(s) stored in the lock's 

memory (maximum 24) can open that lock.
  - 

Safe Deposit Box Mode

:

 the lock emulates safe deposit box operation. To open the lock, all 

the keys in controller database (max. 26) must be 

swipe

 to it, one after another.

  - 

Custom Mode

:

 you can design your own custom operational logic, subject to your needs. 

Then obtain updated firmware from the Manufacturer and download it into the lock with 

           

an

 

RF-1996

 adapter.

Programming of operational modes, Master and User cards, is done via Reset button on the 
lock's case (see Chapters 4 to 11) or via 

Lock Manager

 software using an 

RF-1996

 adapter 

(see Chapter 12). Selected modes and cards database are stored in the lock's NVRAM (non-
volatile memory).
After one of the modes selected and all configuration done, the lock starts to work according to 
these rules:
On key 

swipe

 to the lock's reader, 

  -

 

if the token has access granted, a beep sounds and the LED flashes

 

green, or else

  -

 

if the token has access denied, a beep sounds and the LED flashes

 

red.

Z-

395

 EHT

www.ironlogic.

me

Z-395 EHT 

RFID 

Electronic Furniture Lock

with EM-Marine & HID ProxCard II &

 

Atmel

 

(T5557) reader

 

(

125 

kHz) 

and standalone controller

User Manual

page 1

Summary of Contents for Z-395 EHT

Page 1: ...erized logging and lock setup Only works with Lock Manager software General Mode a typical lock controller operation only the key s stored in the lock s memory maximum 24 can open that lock Safe Deposit Box Mode the lock emulates safe deposit box operation To open the lock all the keys in controller database max 26 must be swipe to it one after another Custom Mode you can design your own custom op...

Page 2: ...rotection against bracelet cloning Locks setup and further use without a PC Note Logic Mode requires special Atmel T5557 keys and Lock Manager software 2 SPECIFICATIONS Working Frequency 125 kHz Keys standards EM Marine HID ProxCard II Atmel T5557 Maximum number of keys Normal 26 Master 4 NVRAM to store settings Present Reading distance 2 4 cm Standby consumption current 30 mkA Audio visual status...

Page 3: ...he locker s wall see Fig 3 4 To mark the hole positions use template from Fig 13 Fig 3 Fig 4 Self tapping Screw 3 5х15 locker s wall Self tapping Screw 3 5х25 push bolt unit Fig 2 A the calculated size depends on thickness of the locker s wall A Connect cable to lock s PCB Note Check that cable socket is firmly connected with lock s PCB socket Install the locking module according to Fig 2 Batterie...

Page 4: ...page 4 Z 395 EHT www ironlogic me How to install the Z 395 EHT lock properly Top view View from inside the door Lock s latch push bolt unit push bolt unit Lock ...

Page 5: ...ws recording the used locker number and battery level into the key bracelet Very convenient when the user forgets which locker he used Allows not to tie up the key to the lock The user will decide which of the free lockers to use Works only with Lock Manager software General mode traditional lock controller operation only the keys recorded in lock s database can open the locker Safe Deposit Box mo...

Page 6: ...s and the LED flashes green The key is erased from lock s memory the latch is withdrawn inside the lock The door is now open lock is ready to restart the cycle from the beginning Legend beep once multiple beeps G Green LED R Red LED blink blinking page 6 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a Normal key is in memory Otherwise IN Waiting for Norm...

Page 7: ...er then a beep will sound green LED will flash the key will be erased from the lock s memory the latch will be draw inside the lock The door is now open lock is ready to restart the cycle from the beginning page 7 Z 395 EHT www ironlogic me Action Sound LED Latch What for Default state None None OUT if a locker is occupied otherwise IN Waiting for Normal key assignment Swipe a key G OUT Locker num...

Page 8: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 26th keys G IN Recording Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 5 s R blink OUT Erase All Normal Keys Default state None ...

Page 9: ...Master key 1st time R blink IN Entering Edit Normal Keys mode Swipe Master key 2nd time R blink OUT Entering Edit Normal Keys mode Swipe Master key 3rd time for 6 s R IN Entering Edit Normal Keys mode Swipe 1st 2nd 3rd Max 24th keys G IN Storing Normal Key into the controller Swipe Master key R blink OUT Exiting Add Normal Keys mode After 10 s R blink OUT Erase All Normal Keys Default state None N...

Page 10: ...ns for Lock s Manager software and RF 1996 adapter can be found on the ironlogic me website 10 ERASING OF ALL MASTER KEYS This function erases all Master keys from lock s database leaving only the Normal keys intact Also cancels the currently selected operating mode To erase all Master keys please perform the following steps a Disconnect the power remove one battery or use the switch on external p...

Page 11: ...ced and the lock lacks energy to open the locker please use external power module power the lock via the connector present on the reader and swipe the lock with the key see Fig 10 Batteries are fully discharged If on Normal key swipe the LED is not flashing AND the lock s latch doesn t pop out it means that lock s batteries are fully discharged In Logic mode the lock records the current battery ch...

Page 12: ... portable computer and subsequent bracelets programming 16 OPERATING CONDITIONS Ambient temperature 5 40 C Humidity 98 at 25 C When operating under non recommended conditions device parameters can deviate from specified values 17 LIMITED WARRANTY This Device is covered by limited warranty for 24 months since the purchase date The warranty becomes void if this Manual s guidelines are not followed t...

Page 13: ...iga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be t...

Page 14: ...ut for Z 395 EHT installation onto a wooden chipboard locker Locker s wall 47 35 mm Locker s door Fig 13 A the size is calculated depending on locker chipboard wall thickness A Z 395 EHT www ironlogic me page 14 ...

Reviews: