background image

IPU 40151 Issue 1 

 

         

                              1 of 16 

IRISYS 

Universal Thermal Imager 

Type IRI 1020

 

                             

User Manual 

 

 
Safety Warning. 
The equipment described in this document uses a Class 2 laser. Under no account should anyone look 
directly into the laser beam or the laser beam exit aperture, irreversible damage to the eye may occur. The 
laser should not be operated when there are personnel in the imager’s field of view. 
Caution – use of controls or adjustments or performance of procedures other than those specified in this 
document may result in hazardous laser radiation exposure.  

 
 

 

 

 
 
 
 

InfraRed Integrated Systems Ltd.

 

Park Circle, Tithe Barn Way  
Swan Valley  
Northampton 
NN4 9BG 
United Kingdom 
Tel +44 (0) 1604  594 200 
Fax +44 (0) 1604 594 210 
Email: 

[email protected]

  

Website: 

www.irisys.co.uk

  

 

 2007 InfraRed Integrated Systems Ltd. No part of this publication may be reproduced without prior permission in writing from 

Infrared  Integrated  Systems  Ltd.  This  document  gives  only  a  general  description  of  the  products  and  except  where  expressly 
provided shall form no part of any contract. From time to time changes may be made in the products. 

 

Summary of Contents for IRI 1020

Page 1: ...ocedures other than those specified in this document may result in hazardous laser radiation exposure InfraRed Integrated Systems Ltd Park Circle Tithe Barn Way Swan Valley Northampton NN4 9BG United...

Page 2: ...TTONS 8 3 0 IMAGE ADJUSTMENT 9 4 0 USER SETTINGS 9 5 0 USING THE LASER POINTER 10 6 0 THERMAL IMAGE TRANSFER FROM IRI 1020 TO A PC 10 7 0 INSTALLING SOFTWARE ON A PC 11 7 1 OPERATING IRI 1020 IMAGER S...

Page 3: ...as seen in figure 1 inspect all the items If any item is damaged or missing notify your dealer immediately Figure 1 Imager toolbox 1 3 Powering the IRI 1020 The IRI 1020 Thermal Imager operates from e...

Page 4: ...ly into the socket on the side of the IRI 1020 imager as seen in figure 4 3 Attach the appropriate supplied regional adapter to the power supply 4 Plug the power supply into a mains socket 5 Switch on...

Page 5: ...tment power button and the door to the SD card slot Figure 5 The IRI 1020 Hardware Safety notice The laser used in this device is designated Class 2 Under no circumstances should personnel look straig...

Page 6: ...fore some of the IR picture will have come from the surrounding background The average background temperature must therefore also be entered into the camera Measurement accuracy falls at low emissivit...

Page 7: ...any time will restore a usable picture Powering the unit off and on again will restore all factory settings Over and under range values are indicated by red or blue coloured numbers these readings ex...

Page 8: ...ged by use of the up down left and right directional arrow keys Palette The user can select from three options The palettes are Red Blue Green Blue or Greyscale and are selected by toggling the up dow...

Page 9: ...his button toggles between auto and manual mode In auto mode the imager continually adjusts the level and span to achieve the optimum image In manual mode it is possible to manually control the level...

Page 10: ...Figure 12 Inserting the SD card 4 Insert the USB connector of the SD card reader into a USB port on the PC using the extender USB cable if required 5 Follow the card reader s installation instruction...

Page 11: ...but it is advisable to leave it as the default The installation will also put a Shortcut Icon onto your PCs desktop to allow quick and easy start up of the software 7 1 Operating IRI 1020 Imager Softw...

Page 12: ...present the upper and lower values of temperature from black cold to white hot 7 4 Thermal Imager Tool Bar Figure 14 Tool bar Save About Edit Colour Map Single Auto Gain Edit Emissivity Toggle Control...

Page 13: ...ng windows and allows the user to control how they are displayed The options available are Cascade Cascades all open images Tile Displays all open images simultaneously Arrange Icons Arranges the Icon...

Page 14: ...sitioned chopper blade 9 2 Emissivity Lookup Table Below is a list of approximate emissivity values for a range of materials for making more accurate temperature measurements NOTE Emissivity values of...

Page 15: ...e complete the details below and send it back to IRISYS at the address on the front page of this manual Name Company Name and address Contact Details IRI 1020 Thermal Imager Serial number This can be...

Reviews: