background image

 

Line Scan Camera 

User’s Manual 

V1.0.0 

Summary of Contents for L5022CG141E

Page 1: ...Line Scan Camera User s Manual V1 0 0...

Page 2: ...data controller you might collect the personal data of others such as their face fingerprints and car plate number You need to be in compliance with your local privacy protection laws and regulations...

Page 3: ...the functions operations and technical data If there is any doubt or dispute we reserve the right of final explanation Upgrade the reader software or try other mainstream reader software if the manual...

Page 4: ...nstallation Requirements Observe all safety procedures and wear required protective equipment provided for your use while working at height Do not expose the device to direct sunlight or heat source D...

Page 5: ...3 4 1 Trigger Type 10 3 4 2 Trigger Source 12 Trigger Delay 16 3 5 I O Control 16 3 6 3 6 1 Non isolated Differential Signal 17 3 6 2 Non isolated Single ended Signal 17 3 6 3 Isolated Single ended S...

Page 6: ...t can work stably in various harsh environments highly reliable and cost effective The GigE line scan camera uses high performance photosensitive chip and it supports real time transmission of image d...

Page 7: ...le image data formats Compatible with CameraLink or GigE protocol and GenICam standard 12 24 VDC wide voltage power supply Conform to CE FCC UL and RoHS Typical Networking 1 3 The most typical network...

Page 8: ...rtain air flow is required Status Indicator Lights 1 5 Table 1 1 Description of status indicator lights Status Indicator Status Description Normal Red Flashes quickly Device starting Blue Dim The addr...

Page 9: ...ure 2 2 Click Features and then configure the camera Step 2 Table 2 1 Description of MV Viewer parameters No Parameter Description 1 Menu See Table 2 2 for details 2 Device list Includes GigE USB Came...

Page 10: ...lect File Recent and then the software displays 10 files that you have recently opened in MV Viewer Click the name of a file to open it directly Save Save changes to the current file Save as Save the...

Page 11: ...6 Menu Description Language Language Chinese and English are available...

Page 12: ...wer the line scan rate Bandwidth The larger the bandwidth of the camera the more data can be transmitted per second and the higher the line scan rate Image transmission mode When the camera works with...

Page 13: ...ate the camera captures images at the actual rate If the maximum line scan rate of the camera is greater than the defined rate the camera captures images at the defined rate Capture frequency Figure 3...

Page 14: ...frame If there are no enough line signals within this time the camera will blacken the remaining lines and output a frame of image Select AcquisitionControl and then configure time of FrameTimeout Fra...

Page 15: ...ion lines reaches the height of the image one image will be generated and then the images will be continuously generated in this mode until the generated images reaches the value defined in Acquisitio...

Page 16: ...the camera Adaptive line height The maximum line height that can be continuously captured in a high low level area of the camera after configuring other camera parameters When the adaptive line height...

Page 17: ...2 Trigger Source Software trigger Select Trigger Software from AcquisitionControl TriggerSoftware to send trigger signals manually through the software I O trigger The trigger signal enters the camera...

Page 18: ...edge and FallingEdge falling edge 3 When setting the trigger you also need to configure corresponding parameters on the software of the capture card that the camera actually connects Select trigger s...

Page 19: ...verse signals will be displayed in RotaryEncoderReverseCounter When it rotates forward continuously the reverse count will decrease and an image will be generated when the count reduces to zero elimin...

Page 20: ...decrease line scan rate Frequency division and multiplication Figure 3 17 3 4 2 2 2 Operation The image line height is 2048 the theoretical line frequency is 28000 and the frame rate is 0 5 fps The i...

Page 21: ...s an image The camera captures an image after the defined trigger delay Working principle of trigger delay Figure 3 21 You can configure Trigger Delay The unit is s and the range is 0 s 10000000 s tha...

Page 22: ...at supports non isolated differential input Use a shielded twisted pair generally the lead of the encoder is a shielded wire to connect the encoder and the camera If you need to extend the wiring use...

Page 23: ...sistance value is generally between 1 10 K depending on the power supply voltage of the encoder The resistance can be 1 8 W metal film in line resistance See Table 3 2 for the recommended values Table...

Page 24: ...switch signal and it can be used to control external devices such as alarm lights light sources and PLCs The trigger output signal can be realized in two ways Level inversion and output signal You ca...

Page 25: ...ine scan cameras Turn on FPNEnable Step 1 Cover the camera with the lens cap and then click FPNBlackCalibration Step 2 Remove the lens cap place an even plate to cover your field of view use a piece o...

Page 26: ...gain can amplify the signal after analog to digital conversion Similar to analog gain the larger the parameter the stronger the gain the brighter the image and also more noise more noise than analog...

Page 27: ...ector and BalanceRatio white balance Once Automatically run white balance for a period of time according to the scenario and then stop Continuous Automatically and continuously adjust the white balanc...

Page 28: ...n Gamma 3 12 It is a non linear correction of the image data due to non linear response of the display The larger the Gamma value the darker the image The range is 0 3 99998 Gamma Figure 3 39 Adjust t...

Page 29: ...Medium Deca and Full TimeSlots It is One by default BaudRate Baud rate PixelClock The clock frequency of pixel transmission The larger the value the faster the transmission FrameTriggerCount Statisti...

Page 30: ...25 3 13 2 GigE Line Scan Camera Transmission Layer GigE line scan camera transmission layer 1 Figure 3 42...

Page 31: ...ount The number of logical channels currently connected GevInterfaceSelector The number of device network ports It is 0 by default GevLinkSpeed The negotiated rate of the current network port GevMACAd...

Page 32: ...e Displays the number of logic channels that the device supports GevPersistentIPAddress Static IP address of the device GevPersistentSubnetMask Subnet mask of device static IP GevPersistentDefaultGate...

Page 33: ...nnel GevStreamChannelSelector Select the streaming channel number if the camera supports multiple streaming channels GevSCPinterfaceIndex Displays the logic channel of device GevSCPHostPort Port of th...

Page 34: ...e image in the test mode has similar problems This function is disabled by default In this case the image output by the camera is the data collected in real time You can configure test mode from TestI...

Page 35: ...ector output Collector signal output Figure 3 45 Voltage output is based on an open collector output circuit A pull up resistor is connected between the power supply and the collector so that stable v...

Page 36: ...e failure There is jitter or interference on site such as jitter of mechanical transmission device and electrical cable interference The encoder and the motor shaft are not fixed tightly and there are...

Page 37: ...he signal wires are routed separately from high current power cables such as motor wiring Install the device separately from high power or high frequency device What do the phase A phase B and phase Z...

Page 38: ...encoder outputs before phase A CW and CCW Figure 3 51 How to convert the signal output by NPN into the signal output by PNP Connect a pull up resistor between the NPN output pin and the encoder power...

Page 39: ...power supply ground 0 V 2 Camera Power Camera power Camera power VCC 3 IN Line5 RS422 input Line5 Connects the encoder frame trigger 4 IN Line5 RS422 input Line5 Connects the encoder frame trigger 5...

Page 40: ...input to connect to the encoder and provide line trigger signal Use optocoupler input to connect photoelectric switch or PLC output to provide frame trigger signal If there is no optocoupler input use...

Page 41: ...8 K network port CL L5082MG170E L5082MK170 E Table 3 11 Second generation line scan camera CMOSIS 4 K network port L5022MG141 E L5022CG141 E L5042MG141 E L5042CG141 E Table 3 12 Third generation line...

Page 42: ...ection to device especially storage devices For example place the device in a special computer room and cabinet and implement well done access control permission and key management to prevent unauthor...

Page 43: ...thorization Check device log By viewing the logs you can know the IP addresses that were used to log in to your devices and their key operations 12 Network Log Due to the limited storage capacity of t...

Reviews: