iPB4 Biometric Device Range
–
Installation & User Guide
–
Rev 07 ©2017-2018 iPulse Systems
16
SECTION 5
IntelliRelay™ CONNECTION
The
IntelliRelay™
v4 acts as the main connection point between the
iPB4 biometric device and the outside world.
The section on the left of the
IntelliRelay™
is reserved for Inputs, whilst
the section on the right provides output. The
IntelliRelay™
is designed
to function on 12
–
14 V DC and should be connected to a Power Supply
providing at least 1.5A, especially if the device is being used to trigger
a mag lock or electronic door striker.
Inputs
•
Door Status
–
connection terminals for the door status monitor,
used to determine the state of a door (or another connected
device)
•
Battery Backup
–
this allows the relay to determine if it is running
off a battery backup unit and to send notifications if configured to
do so.
•
Power
–
connection terminals for the power supply, providing
power to both the IntelliRelay and the connected iPB4.
Note that whilst this unit has significant protection against
electrical surges, polarity is still important. Incorrect wiring could
severely damage the
IntelliRelay™
.
•
Fire Line
–
connection terminals for a fire system. This needs to be
turned on with a switch INSIDE the IntelliRelay™ to
operate and
requires the presence of a 5v signal to keep operating.
•
Pushbutton
–
connection terminals for an exit button or touchless exit sensor.
•
Network Input
–
incoming network connection is plugged in here and passed through to the iPB4 to
simplify installation and avoid exposing a network point to the outside world.
Outputs
•
Relay
–
connection terminals for the on-board relay. Provides
Normally Open (N/O), Normally Closed
(N/C)
and
Common (COM)
terminals.
•
Wiegand Out
–
connection terminals for Wiegand output, allowing communication with Wiegand-
compatible controllers and similar devices. Also allows for feedback from a controller if wired correctly
and configured for this response in
IQ
Suite.cloud
.
•
IntelliLink
–
connection terminals for the IntelliLink connection that allows several
IntelliRelays™
to be
daisy-chained to support additional functionality through use of a single device.
•
Reader Connection
–
RJ45-type connector used to provide power and communications to a connected
iPB7.