background image

1

T-780K operation manual

一、

T-780K system features:

1

The controller has 8 output ports, each port can carry up to 170/512/768 pixels(Different pixels for different

chips).

2

The controller port output two kinds of signal protocol: ①DMX512/1990 international standard protocol and

DMX512 extended protocol; ②SPI/TTL serial protocol.

3

The controller output port provides three protections to ensure that the controller output port is not burn out in

the case of short circuit or reverse connection in the controlled lamp.

4

Controller ID automatic/manual numbering function, which can be numbered together with multiple controllers,

or individual controller numbers.

5

The controller comes with built-in effects to test on-load luminaires (all supported by RGB/RGBW luminaires).

6

The controller has DMX512 write function and address test. The single port or all ports carry the DMX512 IC

write address and perform address test on the luminaire.

7. The communication between the controllers adopts the international standard TCP/IP network protocol. The

optional transmission rate supports 100M/Gigabit adaptation, and the transmission speed is more stable and
fast. The maximum transmission distance between each two controllers can reach 100 meters. More than this
distance can increase the switch or use fiber for long-distance transmission.

8

The controller provides an LCD screen display that shows the model, ID, and operating status of the controller.

9

When connected with our online video software LedPlayer for computer control, the connection status of the

controller is monitored in real time on the computer. Using the online video software LedPlayer for computer
control can realize: program timing playback, program segment selection, effect brightness adjustment, white
balance online adjustment, program playback speed adjustment, display text, picture loop playback, etc., which
greatly satisfy the customer's application and Multiple needs in debugging.

10

The online video software LedPlayer comes with Gamma correction, which makes the color display more

delicate and vivid.

Summary of Contents for T-780K

Page 1: ...7 The communication between the controllers adopts the international standard TCP IP network protocol The optional transmission rate supports 100M Gigabit adaptation and the transmission speed is more...

Page 2: ...s Software select T 780K Support chips Max support light Reamrks International standard DMX512 like UCS512 SM512 TM512 GS512 etc 4096 pixels Suggest to carry 2400 pixels UCS19 ucs29 ucs89 ucs1603 ucs5...

Page 3: ...nal input network port The upper output is connected to the controller IN OUT is connected to the next level controller INPUT Strobe with signal input OUTPU T Cascaded signal output network port OUTPU...

Page 4: ...ent MADRIX control setting Chip selection Mode selection Speed Speed Remarks Normally boot into normal mode the button has no effect Press SET to boot and enter parameter setting function setting Pres...

Page 5: ...Test Lamp address test mode See 7 3 Lamp Address Test Mode for definition in this book MADRIX control The definition refer to this book 8 MADRIX control mode Wiring diagram 1 Computer online wiring d...

Page 6: ...signal output pirt wiring diagram Regular laight wiring diagram DMX512 differential signal wiring diagram DMX512 single signal line wiring diagram DMX512 differential signal wiring diagram AB wire to...

Page 7: ...n operate T 780K numbering has three methods Computer number recommended master number and branch number 1 Controller computer software port numbering 1 1 The computer and the controller are connected...

Page 8: ...the main control display enters the numbering page the SPEED button and the SPEED button adjust the number of the starting sub control as shown below 2 3 After completing the number setting press the...

Page 9: ...the controller will be powered on and enter the manual coding mode The display shows ID 0001 as shown in the figure ie the current number of the controller is No 1 press the SPEED and SPEED keys adjus...

Page 10: ...mode Note When the controller is numbered the cascaded networking ports must be connected in strict accordance with the controller silkscreen prompt INPUT OUTPUT T 780K parameter setting and function...

Page 11: ...and enter the built in effects mode 1 4 Press SET to switch the IC model IC model list 1 DMX standard 250Kbps 5 TM1803 2 UCS1903 6 GS8205 3 SM16703 7 DMX 500K 4 WS2811 1 5 Press MODE to switch the bu...

Page 12: ...of 0 255 IC Chip model Rfer to DMX512 IC list PORT NUM Address port Refer to the port list RETURN Return to the main interface 2 4 Press the MODE button to move the corresponding item of the arrow an...

Page 13: ...oller displays the following picture 2 8 Press the MODE button again to enter the MC manual test mode SPEED and SPEED can adjust the pixel points long press speed or speed can be quickly incremented o...

Page 14: ...test AC ALL CH MODE R G B W 4 channel automatic test MC ALL CH MODE R G B W 4 channel manual test Note 1 Automatic and manual test mode switching AC is the automatic test mode MC is the manual test m...

Page 15: ...Gigabit rate 5 1 Press the SET button and the controller will start up enter the parameter setting and other function interface 1 5 2 Press the MODE button to move the arrow to select 100 BASE 5 3 Pr...

Page 16: ...are LedEdit K setting suggest to use 2 Computer software setting LedPlayer K 3 The controller manual setting 1 LedEdit k software setting MADRIX parameter 1 1 Open LedEdit k V4 9 4 and above edition s...

Page 17: ...the MADRIX mode 2 Set the carry light units number Click on the drop down arrow for this option and select 1 2 3 unit which is the number of units loaded on the controller per port NOTE 1 If the cont...

Page 18: ...s 1 24 the second controller occupies 25 48 and the third controller occupies 49 72 And so on NOTE 4 The T 780K control system supports up to 2048 units of output 170 pixels per unit 3 Support lamps I...

Page 19: ...MADRIX Turn on off MADRIX software 2 SET Univ Set support lights quantity 3 SET IC support IC selection Note The parameters need to be set and set in order of 1 2 3 and the controller will be restarte...

Page 20: ...to complete the selection press the SET button to exit and return to the MADRIX setting interface 3 2 Set the number of lamps on board 1 Press the SET button and the controller will start up and enter...

Page 21: ...and select the model of the loaded IC as shown below 3 Press SET to confirm the entry and set the number of lamps on load as shown below 1 DMX DMX512 IC lamps 2 UCS1903 UCS1903 IC lamps 4 Press the SP...

Page 22: ...d 1 paper box 1 Precautions 1 Controller and controller controller and master controller and computer The network cable of more than five types of specifications between each two nodes can be cascaded...

Reviews: