3.1 Connection cable
An 8-pole, shielded connection cable (cable socket) is required.
We recommend the ipf connection cables with the following article numbers:
•
VK205A21/25 (Length 2m, M12 socket angular/straight)
•
VK505A21/25 (Length 5m, M12 socket angular/straight)
•
VKA05A21/25 (Length 10m, M12 socket angular/straight)
Other cable lengths are available.
When the analog output is used, the cable length affects signal noise. Signal noise increases the longer the
connection cable is.
Analog output I_OUT
Noise: 5.92 uA (1 Sigma) (10 m cable and 680 ohm)
3:59 uA (1 sigma) (2m cable and 680 ohm)
Analog output U_OUT
Noise: 4.80 mV (1 Sigma) (10m cable and 100 kOhm)
3:03 mV (1 Sigma) (2m cable and 100 kOhm)
ATTENTION!
Laser class 1 laser beam according to EN 60825-1:2007. This product can be
operated safely without any additional safety precautions. Nevertheless direct
contact between the eye and beam should be avoided.
ATTENTION!
The IP protection class is valid only if all connections are connected as
described in the technical documentation.
ATTENTION!
Connection, installation and commissioning may only be performed by qualified
personnel.
ATTENTION!
Incorrect supply voltage will destroy the device!