Hide the reference surface
The fact that everything is hidden below the reference surface, the originally teached-in reference surface can
be hidden by shifting the reference surface upwards.
Example:
While using the Delta Height function (Maximum height minus minimum height of the object) the teached-in
reference surface affects the measurement result.
With setting CORRECTION -5 mm, the reference surface is placed over the originally teached reference
surface, which the surface disappears and no longer affects the measurement result.
NOTE
As soon as FLEX MOUNT is activated, SCALE OUT, FIELD OF VIEW and
DIGITAL OUT are reset to the standard settings (SCALE OUT and FIELD OF
VIEW = maximum measuring field, DIGITAL OUT = End of measuring range Sde).
NOTE
If the reference surface should not be moved, the item CORRECTION must be
saved with 0 mm by pressing SET for 2 seconds.
NOTE
If the reference surface is displaced by entering a negative value upwards with
CORRECTION, then the measured value of the functions Max, Min and Average is
reduced by this value, or falsified. For these functions OFFSET in ANALOG OUT
Menu should be preferred. With OFFSET the reference surface at the originally
learned point remains.
Teached-in reference surface
New position of the reference surface. Everything underneath is hidden.
CORRECTION = Move the teached-in reference surface (-x mm)
Summary of Contents for PY740025
Page 1: ...Manual for PY740025 26...