MANUAL [
PY740025/26
]
•
Subject to alteration! Version: 22.10.2018
ipf electronic gmbh
• Kalver Straße 25 - 27 • 58515 Lüdenscheid
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
4.3 The reference surface
If the height of the object is to be measured from a specific surface or the sensor is mounted at an angle up to
±30°, then the reference surface must be taught in with the FLEX MOUNT function.
The following points must be satisfied for teaching in the reference surface:
•
The reference surface must lie within the measuring range of the sensor.
•
The sensor may be inclined at a maximum angle of ±30° to the reference surface.
•
The "Maximum reference surface unevenness"
must not exceed the maximum value.
•
The length of the reference surface must not be less than the "minimum reference surface length"
value.
1
According to data sheet chapter 6.1
NOTE
The reference surface…
•
should be as flat as possible
•
should cover the entire measuring range (width) if possible
•
can be teached-in with the FLEX MOUNT function
Reference surface
Object
Min. reference
surface length
Angle:
(0° shown)
Summary of Contents for PY740025