background image

Vista Panel Wiring and Programming

 

                             Vista Keybus & Tip/Ring Wiring

Dual-Path Alarm Communicator - Installation Guide ...............................................

Page 18

Summary of Contents for BAT-CDMA-WIFI

Page 1: ...Rev 1 1...

Page 2: ...services ipDatatel engineers and manufactures innovative security and automation devices for the alarm industry As a leader in the design and development of Cellular and IP connected products we offer...

Page 3: ...details Programming for TELCO use on Vista Section Universal Wi Fi BAT as Sole Communicator 41 Enter Phone Number 43 Enter Account Number 193 Enter 1 0 Enable to turn on Address 20 GE NETWORX See pag...

Page 4: ...isioning 9 Board Button Configuration 10 Pre Installation 10 Troubleshooting Diagnostic Information 13 Validating the Installation 13 Wiring Programming for Popular Panels 13 DSC Panel Wiring and Prog...

Page 5: ...software enables remote manage ment of Honeywell and DSC alarm panels that are connected to the BAT CDMA WIFI Product Key Features Cellular Verizon CDMA and Wi Fi Communicator The BAT CDMA WIFI replac...

Page 6: ...t runs from any Internet connected browser that supports flash Alarm Notifications via Text Push and Email The BAT CDMA WIFI provides notifications for alarm supervisory trouble open close and test si...

Page 7: ...e A QuickStart Guide has been designed to make the BAT CDMA WIFI easily join the customer s Wi Fi Network This guide can be found at www ipdatatel com support php Connecting to a Wireless Network AP C...

Page 8: ...r into WPS mode LED 6 will blink as long as the device is in WPS mode Follow the router s directions to turn WPS on Typically enabling WPS involves simply pressing a button labeled WPS on the customer...

Page 9: ...es IP connectivity to the BAT CDMA WIFI Resolution The following steps will re provision the BAT CDMA WIFI with the Verizon network Service Provisioning Steps 1 To begin ensure that the device is powe...

Page 10: ...sly attached to Should any pairing issues occur press the SW1 button 5 times to factory reset and start the pairing process over Pre Installation Hardware Registration Before installation of your BAT...

Page 11: ...ion The BAT CDMA WIFI s signal collection requires the alarm control panel send Contact ID format signals from its digital dialer Wire the Telco side of the alarm control s Tip Ring to the BAT CDMA WI...

Page 12: ...eractive Ready See Supported Panels section page 26 27 the following programming will provide full feature virtual keypad access allowing the customer to enter their code to arm disarm the system by w...

Page 13: ...rching for a router in WPS mode Solid Indicates the device has found a router via WPS Mode LEDs 3 to 6 When connected to a Wi Fi Router Displays signal strength indicated on device startup and updated...

Page 14: ...DSC Panel Wiring and Programming DSC Keybus Tip Ring Wiring Dual Path Alarm Communicator Installation Guide Page 14...

Page 15: ...PC Link Connection This provides for remote downloader functionality with ipDatatel s Universal Downloader uDownloader software DSC PC Link Wiring Dual Path Alarm Communicator Installation Guide Page...

Page 16: ...or BAT as Failover w Add l Com munication Device BAT as Dual Re porting w Add l Communi cation Device Code Summarization 015 Disable Option 7 If GSM Dis able Option 7 If Phone Line Enable Option 7 f G...

Page 17: ...e Option 1 Enable Option 1 5 Enable Option 1 2 5 Options to turn on off maintenance for telephone 1 option 1 telephone 2 option 2 and alternate communications option 5 376 Enable Option 1 Enable Optio...

Page 18: ...Vista Panel Wiring and Programming Vista Keybus Tip Ring Wiring Dual Path Alarm Communicator Installation Guide Page 18...

Page 19: ...ng a Honeywell Vista for the BAT CDMA WIFI as Sole Communicator Sec For BAT as Sole Communicator Code Summarization 41 Enter Phone Number 43 Enter Account Number 49 Enter 5 For All Communications to B...

Page 20: ...el manual for your particular application requirements Dual Reporting Setting to 5 sends all reporting to both primary and secondary 54 Enter 0 Enter 2 Enter 0 The time it takes for the communicator t...

Page 21: ...GE Panel Wiring and Programming GE Keybus Tip Ring Wiring Dual Path Alarm Communicator Installation Guide Page 21...

Page 22: ...oncept Programming on GE NetworX Section BAT as Sole Communicator Code Summarization Device 0 Location 0 Enter the Phone Number Device 0 Location 1 Enter Account Number Device 0 Location 2 Enter 13 Re...

Page 23: ...ogram the panel Phone Number into the panel Program the Customers Account Number into the panel Program Reporting codes into the panel Program panel to transmit in Contact ID format For interactive ke...

Page 24: ...m panel wiring is needed A programmable output on the alarm panel will be used to signal the BAT Y Tx terminal that the panel has entered Arm Disarmed state The Z1 output on the BAT CDMA WIFI will be...

Page 25: ...r specific installation Honeywell Typical 56 program zone as type 77 80 Menu LED Outs Program 17 and 18 zone type 78 and 79 DSC PowerSeries Typical Section 001 Zone must be programmed as a 22 Section...

Page 26: ...Vista 15CN 2 6 YES YES YES Vista 15P 2 6 YES YES YES Vista 15PCN 2 6 YES YES YES Vista 15PSIA 4 0 YES YES YES Vista 20P 2 6 YES YES YES Vista 20PCN 2 6 YES YES YES Vista 20PI 5 0 YES YES YES Vista 20P...

Page 27: ...n should function properly as long as the control transmits Contact ID format through Tip Ring If the panel has the ability to use a Dedicated Open Zone that acts as a key switch you can Arm Disarm fr...

Page 28: ...ll have no liability or obligation under this Limited Warranty or otherwise for merchantability or fitness for any particular use nor shall it extend its Limited Warranty if the product is altered or...

Page 29: ...d including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules Th...

Page 30: ...le Cet quipement g n re utilise et peut mettre des fr quences radio et s il n est pas install et utilise en conformit avec les instructions peut causer des interf rences nuisibles aux communications r...

Page 31: ...ided 12v DC Typical Current 130 mA Max Current 185 mA Environmental Temperature Range 30 to 70 C 22 to 158 F Humidity 0 to 95 non condensing Physical Height 7 05 inches Width 4 45 inches Depth 1 5 inc...

Page 32: ...IPD CDMA WIFI IM 3 15...

Reviews: