English
- 23 -
FIG. 9
USING THE ACCESSORIES.
The high pressure washer has a nozzle with a flat angle jet for
cleaning large surfaces.
ROTARY HEAD (optional accessory)
The high pressure washer can be fitted with a head with rotary
nozzle to clean the most stubborn dirt.
Danger:
Aim the jet from a certain distance to avoid damage caused by
the high pressure.
Do not aim the jet at people, animals or electrical sockets.
STOPPING THE CLEANER
1
) Switch off the burner by turning the pressure regulator to
pos. "0"
(fig. 7B).
2
) Let the cleaner run with cold water only for at least 30 seconds
to cool down the boiler.
3
) Stop the cleaner by turning the selector switch to pos. "0"
(fig. 7A).
4
) Discharge the pressure from the H.P. hose by pressing the
trigger on the gun.
5
)
Disconnect the water cleaner from the mains electricity
supply via the Solenoid switch or by unplugging the plug from
the socket.
6
) Turn off the water supply tap (fig. 5A).
Warning
- If the water cleaner is left, even temporarily, turn it off by using
the Solenoid switch or by unplugging the plug from the socket.
- Water cleaners with the "Total Stop” device should be consid-
ered as off when the Solenoid switch is in the “O” position or
the plug is unplugged from the socket.
- When the water cleaner is not used, close the safety device
on the handle.(fig. 9).
- Dry use of the water cleaner causes serious damage to pump
gaskets.
FIG. 7
FIG. 8
USING
THE CLEANER
CONTROL PANEL
A
- On/off switch
B
- Temperature regulator
STARTING THE CLEANER
1
) Turn on the water supply tap (fig. 5A).
2
) Connect the water cleaner to the mains electricity supply by
plugging the plug into the socket.
3
) Start the cleaner by turning the selector switch to pos. I
(fig. 7A).
Warning
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
4
) Press the trigger on the gun and begin washing.
5
)
To operate the water cleaner with hot water,
turn the tempe-
rature regulator to the recommended washing values.
(fig. 7B).
Warning
In water cleaners with the “Total Stop” system, the motor starts
and stops when the lever on the lance handle is actioned or
released.
Danger
Do not block the handle lever in the delivery position.
IMPORTANT!
To eliminate any impurities
or air bubbles from the wa
-
ter circuit we advise starting
the cleaner for the first time
without the lance and letting
the water run out for a few
seconds.
Impurities could block the
nozzle and cause malfun-
ction (Fig. 8).
!
!
!
!
!
0°
MAX
120°C
250°F
65 °C
140°F
0°
MAX
120°C
250°F
65 °C
140°F
A
B
Summary of Contents for D 1713P T
Page 81: ...81 30 mA B A C B A C Chemical Chemical...
Page 82: ...82 EN 12729...
Page 83: ...83 1 IEC 60364 1 3 IEC 60364 1...
Page 84: ...84 3 3 30 30 Total Stop...
Page 85: ...85...
Page 86: ...86 25 250 360 3600 2 1 FIG 1 2 3 FIG 2 FIG 3 D ie se l D ie se l Chemical Chemical...
Page 87: ...87 EN 12729 5 5 200 800 kPa 29 116 2 50 122 F 5 6 3 1 FIG 5 FIG 4 FIG 6 B A C B A C...
Page 91: ...91 200 300 200 200 200 500 500 200 1 50 500 100 100 50 RAEE...
Page 92: ...92 ON 30 DS by pass Total Stop DS...