Administrator Reset:
The following procedure will reset the default user name and password if you are unable to perform an
Administrator login because the Username and Password information has become corrupted or lost.
To clear the login information (and return all settings to their defaults), do the following:
1. Disconnect the power adapter and all cables.
2. Remove the housing from the GCN1000.
3. Short jumper J9 on the circuit board.
4. Reconnect the GCN1000 power adapter.
5. When the front panel LEDs
fl
ash, disconnect the power adapter from the GCN1000.
6. Remove the jumper cap from J9.
7. Close the housing and reconnect the GCN1000 power adapter and cables.
8. After starting back up, you can use the default Username and Password to log in.
Note: Performing this procedure also returns all settings to their defaults. It will not remove Users or their
passwords.