(4) Check again the Voc and Isc of PV string,
Voc of string is 21.6V < 55V (Max. PV Input Voltage) =>OK
Isc of string is 6x8.75A = 52.5A < 65A(Max. PV Input Current) =>OK
Example 2 - How to connect 1200VA model to PV panels with the following
parameters?
• Pmax
:
150W
• Vmp
:
18V
• Voc
:
21.6V
• Imp
:
8.2A
• Isc
:
8.75A
(5) Max. charging current is 60A,
60A/8.2A = 7.31=> max. Number of PV panel in parallel is 7.
(6) Operating Voltage Range is 16~18V,
One PV Panel Vmp 18V is between 16~18V=> max. Number of PV panel in parallel
is 1.
(7) Taking (1) ~ (2) into consideration, and the optimized configuration is 6 PV panels
in parallel, as shown below).
(8) Check again the Voc and the Isc of PV string,
Voc of string is 21.6V < 55V (Max. PV Input Voltage) =>OK
Isc of string is7x 8.75A = 61.25A < 65A(Max. PV Input Current) =>OK