![Invest Solar SICM16H24 Instruction Manual Download Page 11](http://html.mh-extra.com/html/invest-solar/sicm16h24/sicm16h24_instruction-manual_2085189011.webp)
Connect the battery cables
• The gauge of battery cables shall be no
less than 6 AWG with 105*C rating.
• No matter how the batteries are connected (in series or in parallel),
make sure the
cables' terminal voltage is consistent with the inverter's specification (12V for
1000VA/1200VA model and 24V for 2000VA/2200VA model).
• It's recommended to cover the battery terminals during the connection.
• Check the polarity of cables before connecting to the inverter.
• Connect the battery cables to the inverter's battery terminals as shown
below.
Connect with single battery
Make sure the battery voltage meets the inverter's specification (12V for
1000VA/1200VA modeland24V for 2000VA/2200VAmodel)
battery
Connect with multiple batteries
While connecting multiple batteries, use the same brand/type for all
batteries. Do not mix the battery bank with different brand/type of
batteries.