USER AND SAFETY INSTRUCTIONS

6

iV-Office ventilation device | Installation instructions

• 

NOTICE: 

The ventilation device is not suitable for drying out buildings. Do not put it into opera-

tion until the construction work has been completed. 

• 

NOTICE: 

Contamination of components, e.g. by plaster residue, will damage the components! 

Seal the ventilation device/air outlets of the ventilation device so they are dust-tight throughout 

the construction work. Do not remove the thread locks until final assembly.

• 

NOTICE: 

Do not install the device near indoor air thermostats or in the immediate vicinity of/

above sensitive pictures or furniture.

• 

NOTICE: 

Observe the specified minimum clearances on both sides of the wall and frontally 

to prevent unintentional mixing of different air flows and to ensure access to the device and its 

components. A minimum distance of 1.2 m must be maintained between adjacent air openings. 

(

, page 14 f.).

• 

NOTICE: 

The wall sleeve must be integrated into the building envelope (airtightness level) in 

accordance with the current state of the art, taking into account construction-related and physi-

cal specifications ("RAL installation"). Material for this is must be provided on site.

• 

NOTICE: 

When bringing the wall construction up to the wall sleeve, observe the necessary 

blocking levels to avoid interrupting the composite thermal insulation system. Consult your 

planner before installation if you are at all uncertain!

• 

NOTICE: 

Install the wall sleeve with a slope of 1 - 2° to the exterior wall to ensure the drainage 

of any condensate that may form.

• 

NOTICE: 

Do not install the ventilation device in places where direct contact with water spray is 

possible. Observe the specifications of VDE 0100 when choosing the installation location.

• 

NOTICE: 

Store components standing outside the wall sleeve and do not throw them to avoid 

damage and breakage of the components, especially the thermal accumulator.

• 

NOTICE: 

In order to avoid algae growth around the external terminations, the instructions 

for installation must be followed exactly (apply all sealing tapes!). We recommend a biocidal 

pre-treatment/water-repellent pre-treatment of the façade surface around the external 

 

terminations. Consult your planner about this!

• 

NOTICE: 

When installing components in (exterior) walls with insulation, use insulation  

wallplugs to ensure that the components are securely fastened. 

Insulation wallplugs are not included in the scope of supply, they are available as an option!

• 

NOTICE: 

Only use permanently elastic sealing compound suitable for outdoor use to seal the 

joints at all external edges!

• 

NOTICE: 

The device has scratch-sensitive plastic surfaces. Do not touch the components with 

oily and/or dirty hands. Avoid contact with sharp or pointed objects, e.g. rings.

Cabling / connection of the reversible fan

• 

CAUTION:

 

The system's electrical connections may only be carried out by qualified 

electricians.

• 

NOTICE: 

The reversible fan operates with protective extra-low voltage.  

It must not be connected directly to the 230 V power grid.

• 

NOTICE: 

Laying cables whose sheathing is not resistant to plastering under plaster leads to 

short circuits and cable fire! Lay cables without a plaster-resistant cable sheath in the conduit.

• 

NOTICE: 

The use of too small a cable cross-section leads to too great a voltage drop and/

or contact is not guaranteed! For the fan BUS, use a cable cross-section of at least 0.75 mm² 

(stranded wire). Use wire ferrules with collars to connect the strands.

•  When using several ventilation devices controlled by several controllers, you must ensure that 

the ventilation devices are synchronised with each other (see installation instructions for con-

trollers). You should connect all controllers via a mains fuse in the house distribution board.

If your device has a fault, contact your nearest distributor or our technical service.

Any kind of use other than the intended use will exclude all liability claims.

Summary of Contents for iV-Office

Page 1: ...Ventilation device with heat recovery www inventer eu Installation instructions iV Office...

Page 2: ...bed com ponents Nevertheless deviations may still occur therefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope For reasons of clarity...

Page 3: ...18 4 2 Create wall opening 19 4 3 Laying the cables to the wall opening of the ventilation device 20 4 4 Installing the wall sleeve 22 4 5 Installing the ventilation device s external termination 24...

Page 4: ...ates the severity of the potential hazard unless the preventive measures are taken DANGER means Imminent danger of serious injury or death WARNING means Possible danger of serious injury or death CAUT...

Page 5: ...s liability insurance association Use the device system exclusively for the applications that are described in this documentation and only in conjunction with components that are recommended authorise...

Page 6: ...e of the components especially the thermal accumulator NOTICE In order to avoid algae growth around the external terminations the instructions for installation must be followed exactly apply all seali...

Page 7: ...he ventilation device Qualified personnel The equipment system may only be set up operated and cleaned in conjunction with this documentation and the documentation for the controllers Installation ele...

Page 8: ...ensure more efficient flow through the thermal accumulator The sound absorbing Inventin lining and the unique geometry of the Xenion EFP reversible fan effectively reduce the passage of sound The stan...

Page 9: ...ion hood base plate 2 Flex Office ring insert pre installed 3 Weather protection hood cover 4 R D250 wall sleeve 5 Recess for controller connecting cable 6 Sound insulation lining Inventin 7 Thermal a...

Page 10: ...extract air After 70 seconds the reversing fan changes the direction of rotation each time After the direction of rotation has changed the heat accumulator releases the stored heat energy to the incom...

Page 11: ...rated wind pressure stabiliser in the Xenion EFP reversible fan the air flow in the system is kept almost constant even in the event of weather related pressure fluctuations Thus the sensitivity of th...

Page 12: ...zone control No No Operating concept Switch Touch Operating modes Heat recovery Unidirectional ventilation OFF standard version only Heat recovery Unidirectional ventilation OFF standard version only...

Page 13: ...ing concept Touch Weekly timer Operating modes Heat recovery Through ventilation OFF Functions Pause function 1 8h per zone Dehumidification with variable air volume flow Fan speed 4 Output levels fre...

Page 14: ...spray is possible Observe the specifications of VDE 0100 when choosing the installation location Minimum distances of the wall opening for the ventilation device Minimum distances to components buildi...

Page 15: ...right 2 Contour of weather protection hood3 3 Reveal 4 Door window frame 5 Bottom edge of lintel4 1 Minimum distance to adjacent components on the interior wall 3 Recommendation Attach the hood at lin...

Page 16: ...iant Figure 3 Sectional drawing of the iV Office ventilation device A Interior plaster interior structure B Masonry C Insulation D Render 1 Inner cover base plate 2 Flair XL adapter 3 Inner cover pane...

Page 17: ...se plate 2 Flex Office insert pre assembled 3 Exterior wall fixing hole 4 Protective grid 5 Weather protection hood cover 6 Drip rail Flair XL inner cover Figure 5 Dimensional drawing of the Flair XL...

Page 18: ...nent 1 External termination 1 a Flex Office WSH cover 1 b Flex Office WSH base plate 1 c Exterior wall fixing elements 1 d Sealing tape 2 R D250 wall sleeve 2 a Styrofoam discs 2 b Mounting wedges set...

Page 19: ...he minimum distances and the installation position of the ventilation device Consult your planner before installation if you are at all uncertain Create the wall opening through core drilling Power dr...

Page 20: ...reversible fan NOTICE Cable to the wall opening of the ventilation device not laid No connection of the reversible fan possible Routing of the cables to the wall opening for the ventilation device mus...

Page 21: ...rminal blocks Ventilation devices Ventilation devices Operated in pairs Operated in pairs Principle sketches for cable laying The corresponding connection diagrams and assembly steps for installing th...

Page 22: ...other superstructures if applicable C Insulation if applicable incl air gap B Masonry incl relining if applicable A Interior plaster X A B C D Cut the wall sleeve to the determined dimension X Be care...

Page 23: ...ing the free space between the wall sleeve and masonry insert styrofoam discs Insert the styrofoam discs into the wall sleeve from the inside and outside NOTICE Interruption of the thermal insulation...

Page 24: ...around the weather protection hood consult your planner regarding this Installing the Flex Office weather protection hood Spirit level pen power drill with 8mm drill bit cordless screwdriver rawl plu...

Page 25: ...he base plate to exterior walls with insulation or when using the Simplex wall installation system use wallplugs for insulation for fixing purposes These are not included in the scope of supply they a...

Page 26: ...t sound Inventin is a sensitive material To safeguard its sound insulating function handle the lining with care Cutter Requirements The external termination is fitted Remove the styrofoam disc from th...

Page 27: ...ilation device Installation instructions Shorten the sound insulation lining on the inner wall side with a cutter so it is flush with the wall sleeve Do not damage the connecting cable on the interior...

Page 28: ...tted The sound insulation lining is inserted Insert the thermal accumulator from the interior into the lined wall sleeve The handle points towards the interior The connecting cables protrude into the...

Page 29: ...the cable entry Before installation check whether any adjustment of the inner cover adapter needs to be made If necessary change the position of the cable entry so that it matches the conditions of t...

Page 30: ...rill the four holes with 6 mm min 40 mm deep Insert the rawl plugs Route the fan BUS from behind through the cable entry of the prepared base plate NOTICE If the base plate of the inner cover is twist...

Page 31: ...ules onto the cables cable cross section 0 75 mm Loosen the plug connections on the reversible fans of the two ventilation devices Align the plug connectors on the ventilation devices so that the clam...

Page 32: ...mode Brown cable DIR2 V in the left pole Green cable VOUT IV in the middle pole White cable DIR1 III in the right pole Reconnect the connected plug in connector to the plug in connector on the reversi...

Page 33: ...VOUT IV Operating voltage Green CCW Black DIR2 V Signal direction 2 Brown DIR1 III Signal direction 1 White The reversible fan is connected to the controller 4 9 Check function and complete fan instal...

Page 34: ...e plate The tab on the filter ring faces the inside and is located in the cut out provided in the base plate Place the panel on the four spacers The position arrows on the back of the inner cover pane...

Page 35: ...e level distance 2 m dB A 14 41 Standard sound level difference dB 43 52 Thermal efficiency of heat recovery w 0 88 Input voltage V DC 6 16 Power consumption W 1 5 Specific fan power input W m h 0 14...

Page 36: ...e following information from the product data sheet Energy efficiency class SEC class Sound power level Lwa Maximum air flow supply air 2016 1254 2014 49 dB A ENERGIA ENERGIJA ENERGY ENERGIE ENERGI A...

Page 37: ...temperature change t 88 h Maximum air flow rate m h 90 i Electrical input power incl control W 9 j Sound power level Lwa dB A 49 k Reference air flow m h 63 l Reference pressure difference Pa 0 m SEL...

Page 38: ...imum air flow rate m h 90 i Electrical input power incl control W 9 j Sound power level Lwa dB A 49 k Reference air flow m h 63 l Reference pressure difference Pa 0 m SEL W m h 0 14 n Control factor 1...

Page 39: ...06 1508 0182 1508 01861 Flex Office weather protection hood Nord RAL 7011 1508 0184 Flex Office weather protection hood anthracite RAL 7016 1508 0183 1508 01871 Flex Office weather protection hood cus...

Page 40: ...mode The rotational speed of the fan is too low Increase the output level Noises Foreign body in the fan Remove foreign body from the fan Clean the ventilation system Thermal accumulator is not correc...

Page 41: ...about the warranty is available at www inventer eu guarantee 9 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immedia...

Page 42: ...Item number 5001 0043 Version 2 0 06 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstra e 4a D 07751 L bersch tz Germany www inventer eu...

Reviews: