INSTALLATION AND ASSEMBLY
30
iV-Office ventilation device | Installation instructions
Requirements:
• The thermal accumulator insert has been installed.
►
Position the inner cover adapter with the base plate
inserted centrally to the wall sleeve on the interior
wall.
►
Align the inner cover adapter including the inserted
base plate with a spirit level.
►
Mark the four corner drill holes.
►
Drill the four holes with Ø 6 mm, min. 40 mm deep.
►
Insert the rawl plugs.
►
Route the fan BUS from behind through the cable
entry of the prepared base plate.
NOTICE: If the base plate of the inner
cover is twisted
, the inner cover panel can-
not be fitted correctly!
• The position arrow on the inner cover base
plate must
always point
upwards
.
►
Screw the base plate into the rawl plugs with the
screws.
The position arrow on the base plate points
upwards.
The inner cover base plate is fitted.
Spirit level, pencil, power drill, cordless screwdriver / Phillips screwdriver, rawl plugs,
screws
ø = 6 mm
40 mm
!
4 x