background image

 
 

BALNAFETTACH HOUSE, PH26 3LW             (01479) 872 518                   [email protected]

 

 

 

MicroFogger keeps charging forever (Battery Charge Indicator Does Not Increase) 

If the MF3 battery level does not increase at all even where it has been charged for several 
hours 

 first make sure the Rocker Switch has been set to the 

ON

 during charging. 

MicroFogger turns on when the USB cable is plugged into it but the other end of the cable 
is not in a charger! 

This can occur when the Charge Lock is 

OFF

.  Some charging cables make the MF3 

recognise them as a 

trigger input

 (a feature that allows the MF3 to be triggered via a 

cable).  To resolve this issue 

 turn the Charge Lock back to 

ON

Microfogger Activates Randomly While Charging 

This can happen if you are using a computer or a power bank to chanrge the MF3.  If the 
computer/power bank goes to 

sleep

 during the charging process, the MF3 may 

inadvertently recognise this as a control cable signal.  To prevent this from happening, only 
use 

wall-socket

 type USB chargers. 

MicroFogger produces a burning smell even with a new heating coil 

 

There may be a very slight burning smell present in the first few second of operation with a 
new coil.  This is normal.  If the smell persists or becomes more noticeable, stop using the 
MF3 and allow it to rest for at least another 30 minutes before switching on again.   

Ensure that the fluid tank is fully filled. In cold environments, the fog liquid becomes more 
viscous (thickens) and will take longer to be absorbed into the heating coil.  

In these situations, place the MicroFogger in a warm area before using it. 

 

Safety Considerations 

The MicroFogger 3 (MF3) is powered by a high-performance Lithium-ion battery. This type 
of battery presents a potential fire risk if handled improperly. The following safety 
guidelines aim to prevent any issues from arising: 

 

Never leave the MF3 charging while unattended 

 

Never charge an MF3 using a computer or a battery bank 

 

Keep the MF3 away from any flammable materials 

 

Do not expose the MF3 to temperatures over 40

0

 

Never attempt to disassemble the MF3 or undertake unauthorised modifications 

 

Don’t expose

 to direct sunlight for extended periods of time 

 

Always ensure the MF3

’s heating coil compartment is clear of debris

 

 

If the MF3 sustains a significant impact through a drop or other mishap, immediately 
cease operation (unplug it if it is charging) and place it in a safe area 
outdoors and wait for at least 10 minutes.  

Summary of Contents for MicroFogger 3 Pro

Page 1: ...ise Double check that a coil is installed it usually is Using the 50ml bottle of fog liquid unscrew bottle cap Using the pipette style tip carefully pour fog liquid into the gap between the inner and outer walls of the reservoir DON T pour into the central part coloured RED in image Don t squeeze the bottle too hard or you ll overfill and spill the liquid Keep filling the fluid tank until the liqu...

Page 2: ...tion to turn the MF3 on for charging or for operation Move to the 0 OFF position to completely turn the device off and especially for storage In the OFF position there will be little or no battery drain Mode Button lower Press to move between FAN SPEED and COIL POWER adjustment Hold down for 4 secs to enter Advanced Settings Menu In Advanced Settings Menu sequentially press to cycle through menu o...

Page 3: ... be pressed again to begin adjusting the speed of the smoke fan power level in the same way as detailed above Throughout this process you can hold the trigger button to see how changes to these settings impact the smoke production in real time To return back to the home screen simply don t press the mode or select buttons for 2 seconds Advanced Settings Menu This interface can be entered by holdin...

Page 4: ...tion By default all 4 Remote Control buttons are available pre programmed for use for various set power levels but once a specific letter is selected the MicroFogger will only be triggered when that button is pressed on the remote This allows for up to 4 independently controlled MicroFoggers RC Program Allows you to bind the MicroFogger to any 433mhz frequency remote control Simply press Select bu...

Page 5: ... you observe this follow the instructions in the storage and maintenance section of this manual to replace the heating coil In extreme cases if you keep running the MicroFogger even after the heating coil has worn out small burning fragments of the absorbent material may be ejected out of the nozzle Although the MicroFogger can be used in any orientation provided that the tank is mostly full we st...

Page 6: ...nk unscrewed ie off the MF3 during storage We always advise if storing for a few days or more to make sure that the tank is fully emptied to prevent the risk of leaks The fog fluid is non hazardous but a bit sticky During normal use a burning smell coming from the MF3 indicates that the heating coil should be replaced Follow the steps below To change the coil 1 Unscrew the MF3 from the fluid tank ...

Page 7: ...a fine screwdriver or other rod like object into the barrel of the MicroFogger the hole from which smoke is emitted while the unit Rocker Switch is turned off Briefly apply light pressure to the screwdriver this will ensure that proper electrical contact is restored Remove the screwdriver and try the unit again Should this error persist replace the coil with a new one Fluid Tank Leaking Ensure bot...

Page 8: ...n the first few second of operation with a new coil This is normal If the smell persists or becomes more noticeable stop using the MF3 and allow it to rest for at least another 30 minutes before switching on again Ensure that the fluid tank is fully filled In cold environments the fog liquid becomes more viscous thickens and will take longer to be absorbed into the heating coil In these situations...

Page 9: ...ok directly into the MF3 s nozzle while it is running Finally a few more sensible guidelines that should be respected Never allow anyone under the age of 18 to use the MicroFogger 2 If the smoke starts smelling burnt immediately cease operation and replace the heating coil with a new one Never leave the MF3 in a car that is exposed to direct sunlight as during hot weather this is likely to cause t...

Page 10: ... in this Manual and to use good judgement together with knowledge of the risks detailed above to safely operate the device If you are unwilling to accept the risks associated with using this device immediately return it for a full refund Support vosentech com Package Contents The following should be included with your standard MF3 Pro Dropper bottle with 50ml of fog liquid Replacement heating coil...

Page 11: ... the micro USB port together To access these pins you can strip the end off a data transferring micro USB cable and then plug it into the MicroFogger WE can provide short cables to use for this purpose as an optional extra Typically when exposed these wires will be green and white but the colour can depend on the exact type of cable used For triggering it is normally the white and green wires that...

Page 12: ...ditive and under normal operations the fog produced is considered to be non toxic However we do not recommend breathing in the smoke The smoke can only become potentially harmful to inhale if the safety precautions regarding the replacement of worn out heating coils are not followed What is the fog liquid The liquid consists of a high purity vegetable glycerine and propylene glycol mixture and is ...

Page 13: ... to put it into cardboard or fabric enclosure you shouldn t encounter any issues On the other hand metal barrier such as car doors will usually block the signal although we have even had luck with activating the MicroFogger while it was inside a car hood Can I control the MicroFogger 2 via a wired remote Yes the usb charging port also doubles as a signal input which allows you to trigger the Micro...

Reviews: