Additional Features 

The following should be included with your standard MF3 Pro.  

The MF3 supports several additional features to make it easier to incorporate the effects 
into your own custom projects.  

Please note that although these modifications are officially supported, you may void your 
MF3 warranty should you decide to proceed with any of these effects as there is a potential 
to damage the internal electronics if they are not followed carefully.  

Whilst the following guides will detail each step to make the process as easy as possible, we 
still advise that you only attempt these modifications if you believe you have sufficient 
technical knowledge. 

Proceed at your own risk

 

Wired Remote Control Operation 

The MicroFogger can be triggered via its USB port to permit automated control or to 
activate the MF3 over long distances (further than the radio Remote-Control operational 
distance). 

This can be done by simply connecting the two data pins (pins 3 and 4) of the micro USB 
port together. To access these pins, you can strip the end off a data transferring micro USB 
cable and then plug it into the MicroFogger.   WE can provide short cables to use for this 
purpose as an optional extra. 

Typically, when exposed, these wires will be green and white, but the colour can depend on 
the exact type of cable used.  

For triggering it is normally the 

white

 and 

green

 wires that are used.  You can now solder 

these wires to a relay or switch of your choice 

but take care not to let the red and black 

wires touch!

 

If you only see two wires after stripping the USB cable, that means that it is a power-only 
USB cable rather than a data+power one so it 

won’t work

 as a signal cannot be sent through 

it.  

In more advanced projects, you can connect the relay to a micro-controller such as a 
Raspberry Pi or an Arduino to allow for precise timing or environment-dependent triggering 
when paired with additional sensors.  

Please note that the 10 second continuous use cut-off is still in place even when the MF3 is 
activated through the USB port. 

 

 Warning! 

 Incorrect wiring or accidental contact between any wires other than the data 

ones can lead to irreversible damage to the MF3 which will not be covered by the warranty. 

 

 

Summary of Contents for MicroFogger 3 Pro

Page 1: ...ise Double check that a coil is installed it usually is Using the 50ml bottle of fog liquid unscrew bottle cap Using the pipette style tip carefully pour fog liquid into the gap between the inner and outer walls of the reservoir DON T pour into the central part coloured RED in image Don t squeeze the bottle too hard or you ll overfill and spill the liquid Keep filling the fluid tank until the liqu...

Page 2: ...tion to turn the MF3 on for charging or for operation Move to the 0 OFF position to completely turn the device off and especially for storage In the OFF position there will be little or no battery drain Mode Button lower Press to move between FAN SPEED and COIL POWER adjustment Hold down for 4 secs to enter Advanced Settings Menu In Advanced Settings Menu sequentially press to cycle through menu o...

Page 3: ... be pressed again to begin adjusting the speed of the smoke fan power level in the same way as detailed above Throughout this process you can hold the trigger button to see how changes to these settings impact the smoke production in real time To return back to the home screen simply don t press the mode or select buttons for 2 seconds Advanced Settings Menu This interface can be entered by holdin...

Page 4: ...tion By default all 4 Remote Control buttons are available pre programmed for use for various set power levels but once a specific letter is selected the MicroFogger will only be triggered when that button is pressed on the remote This allows for up to 4 independently controlled MicroFoggers RC Program Allows you to bind the MicroFogger to any 433mhz frequency remote control Simply press Select bu...

Page 5: ... you observe this follow the instructions in the storage and maintenance section of this manual to replace the heating coil In extreme cases if you keep running the MicroFogger even after the heating coil has worn out small burning fragments of the absorbent material may be ejected out of the nozzle Although the MicroFogger can be used in any orientation provided that the tank is mostly full we st...

Page 6: ...nk unscrewed ie off the MF3 during storage We always advise if storing for a few days or more to make sure that the tank is fully emptied to prevent the risk of leaks The fog fluid is non hazardous but a bit sticky During normal use a burning smell coming from the MF3 indicates that the heating coil should be replaced Follow the steps below To change the coil 1 Unscrew the MF3 from the fluid tank ...

Page 7: ...a fine screwdriver or other rod like object into the barrel of the MicroFogger the hole from which smoke is emitted while the unit Rocker Switch is turned off Briefly apply light pressure to the screwdriver this will ensure that proper electrical contact is restored Remove the screwdriver and try the unit again Should this error persist replace the coil with a new one Fluid Tank Leaking Ensure bot...

Page 8: ...n the first few second of operation with a new coil This is normal If the smell persists or becomes more noticeable stop using the MF3 and allow it to rest for at least another 30 minutes before switching on again Ensure that the fluid tank is fully filled In cold environments the fog liquid becomes more viscous thickens and will take longer to be absorbed into the heating coil In these situations...

Page 9: ...ok directly into the MF3 s nozzle while it is running Finally a few more sensible guidelines that should be respected Never allow anyone under the age of 18 to use the MicroFogger 2 If the smoke starts smelling burnt immediately cease operation and replace the heating coil with a new one Never leave the MF3 in a car that is exposed to direct sunlight as during hot weather this is likely to cause t...

Page 10: ... in this Manual and to use good judgement together with knowledge of the risks detailed above to safely operate the device If you are unwilling to accept the risks associated with using this device immediately return it for a full refund Support vosentech com Package Contents The following should be included with your standard MF3 Pro Dropper bottle with 50ml of fog liquid Replacement heating coil...

Page 11: ... the micro USB port together To access these pins you can strip the end off a data transferring micro USB cable and then plug it into the MicroFogger WE can provide short cables to use for this purpose as an optional extra Typically when exposed these wires will be green and white but the colour can depend on the exact type of cable used For triggering it is normally the white and green wires that...

Page 12: ...ditive and under normal operations the fog produced is considered to be non toxic However we do not recommend breathing in the smoke The smoke can only become potentially harmful to inhale if the safety precautions regarding the replacement of worn out heating coils are not followed What is the fog liquid The liquid consists of a high purity vegetable glycerine and propylene glycol mixture and is ...

Page 13: ... to put it into cardboard or fabric enclosure you shouldn t encounter any issues On the other hand metal barrier such as car doors will usually block the signal although we have even had luck with activating the MicroFogger while it was inside a car hood Can I control the MicroFogger 2 via a wired remote Yes the usb charging port also doubles as a signal input which allows you to trigger the Micro...

Reviews: