6
SYSTEM OVERVIEW: MZ-HOME CONTROLLER
6
MZ-Home | Operating instructions
2
System overview:
MZ-Home controller
The MZ-Home controller is an electronic programming device for controlling inVENTer
®
ventilation
devices with heat recovery.
It features Clust-Air technology (multi-zone control), touch operation and a wide variety of possible
uses.
The MZ-Home consists of an operating unit and (at least one) up to four Clust-Air modules.
Each Clust-Air module controls the ventilation devices in one zone within the accommodation unit.
This allows the MZ-Home to provide individual ventilation for up to four different areas (ventilation
zones) within one accommodation unit. The settings can be made separately for each zone.
On the MZ-Home controller, the operating mode of the ventilation unit, the setting of the air flow
volume, the programming of a 7-day timer and the humidity monitoring is set separately for each
zone.
An external interface also allows the scope of functions to be extended:
• Demand-based ventilation via sensor technology (CO2 sensor, VOC sensor
1)
[NO]), or
• Integration of a safety device (e.g. pressure monitor, [NC]) with simultaneous operation of the
ventilation devices with fireplaces.
• Integration of the MZ-Home controller into an existing building management system via an
analogue input (DC voltage)
Features
• Intelligent Clust-Air
®
technology for control of up to four different areas (zones) within the
accommodation unit
• Illuminated display unit
• Easy operation through capacitive buttons (navigation arrows)
•
Control of the ventilation system in the operating modes heat recovery, ventilation and off
•
Dehumidification function: Automatic humidity monitoring via sensors for automatic dehumidi
-
fication depending on the relative air humidity of the interior
•
Individual definition of the output levels of the reversible fans
•
Pause function for temporarily switching off the ventilation units in a ventilation zone
• Interface for an external input or connection to a home automation system
• Option to connect additional sensors via a potential-free input:
CO
2
sensor, VOC sensor or pressure sensor (fireplace switch)
• Integrated hours-run counter
• Filter change reminder