4 Installation
4.1 Considerations for New Enclosures
Pump manufacturers generally will not allow third parties to modify their pumps because they have
many safety certifications that can easily be invalidated. Therefore if installing into a pump head,
the pump manufacturer MUST perform the necessary modifications for you.
The following factors need to be considered in designing an installation for the G6 OPT:
1. Fire
The enclosure must be designed to meet the requirements of ISO/EN 60950-1 for
FIRE
ENCLOSURES
.
2. ATEX (Explosive Atmospheres)
The G6 OPT has openings that prevent it being gas-tight, and consequently it must be located
away from any hazardous zone. Refer to local laws and regulations for hazardous zones to
determine a suitable mounting arrangement for the G6 OPT. The enclosure in which the G6 OPT
is mounted should also be designed to prevent a dangerous build-up of explosive gases.
3. Security
The enclosure must provide sufficient physical security to protect the public from the
hazards within, and to reduce the possibility of tampering with the OPT.
4. Power & Data
a. The enclosure must provide mains power. The requirements are:
i. A permanently-wired connection or a socket.
ii. A protective earth connection
iii. The outlet
may
be switched if it is a socket, and
must
be switched if it is
permanently wired.
iv. For optimal performance, the recommended power connectivity is one
PSU per G6 OPT. The use of two G6 OPTs on a single PSU may lead to
erratic start up behaviour and is not recommended. If using two G6 OPTs
to one PSU, the two OPTs must have power applied simultaneously to
reduce this risk.
b. The enclosure must provide an Ethernet data connection. The requirements are:
i. Capable of at least 10Mbps (preferably 100Mbps)
ii. The connection must be either a socket into which a standard Ethernet
patch cable can be connected, or a cable that is terminated in a standard
RJ45 plug suitable for direct connection into the OPT LAN socket.
iii. Minimum cable standard should be Cat5e
c. The enclosure may provide an alternative data connection for terminals that have
optional communications modules installed. Please consult with Invenco for what
options are available.
5. Accessibility
The enclosure must be designed and mounted so that disabled persons are able to
operate the OPT.
6. Materials
The enclosure and all its components must be constructed of durable materials suitable
for the intended location.
7. Door cut-out
a. Use the wireframe drawings in Section 8 to determine the extra space required for
the front of the terminal (larger than cut-out).
b. The edge of the cut-outs should be smooth and free of burrs, and the surface of
the door around the cut-out should be clean, and planar within ± 1mm.
8. Hinging
Use the following diagrams as a guide when designing an enclosure and/or door to house
Summary of Contents for G6 OPT 6500x
Page 32: ...Invenco Group Limited Proprietary Confidential 8 Drawings 8 1 Dimensions ...
Page 33: ...Invenco Group Limited Proprietary Confidential ...
Page 35: ...Invenco Group Limited Proprietary Confidential ...
Page 38: ...Invenco Group Limited Proprietary Confidential 9 Typical Wiring ...
Page 39: ...Invenco Group Limited Proprietary Confidential 10 Notes ...