96067 1 09/20
20000 S
Translation of the Original Operation Manual
Übersetzung der Originalbetriebsanleitung
GB
5
IMPORTANT SAFETY NOTES
INITIATION
MAGNETIC FIELDS
Power Supply:
95~105, 105~115, 115~125, 215~225, 225~235 or 235~240, 50/60Hz
Is pre-set in accordance with the respective site of operation.
Power Consumption:
100V:
Under Standby 0.3A While charging 5.0A At the time of ERASE 0.6A
110V:
Under Standby 0.25A While charging 4.5A At the time of ERASE 0.55A
120V:
Under Standby 0.2A While charging 4.0A At the time of ERASE 0.5A
220V:
Under Standby 0.17A While charging 2.5A At the time of ERASE 0.35A
230V:
Under Standby 0.16A While charging 2.25A At the time of ERASE 0.325A
240V:
Under Standby 0.15A While charging 2.0A At the time of ERASE 0.3A
Degausser System:
Capacitive Discharge
Operating Time, Duty Cycle:
Continuous
Erasing time:
< 15 milliseconds
Cycle time:
15 seconds per cycle.
Magnetic Field:
20.000 Oe measured in center.
Max. Media Size:
108mm (4.25 in.)(W) x 31.5mm (1.25 in.)(H) x 149mm (5.86 in.)(D)
Erasing Area Size:
108mm (4.25 in.)(W) x 31.5mm (1.25 in.)(H) x 149mm (5.86 in.)(D)
Media:
2.5 type HDD, 3.5 type HDD, DLT, LTO, 3490 and more
Temperature:
5°C - 40°C (41°F - 104°F)
Humidity:
10%H - 40%H (without condensation)
Weight machine:
47,7 kg (105 lbs.)
Weight shipping:
65 kg (143 lbs.)
Size machine:
430mm (16,9 in.)(L) x 248mm (9,8 in.)(W) x 629mm (24,8 in.)(H)
Warranty:
1 Years Factory Warranty Standard
TECHNICAL DATA
DISPOSING OF THE MACHINE:
Dispose of the machine in an
environmentally sound fashion at the
end of its useful service life. Do not
dispose of any of the parts included
in the machine or its packaging with
household trash.
DISPOSING
MAGNETIC FIELDS MEASURED AROUND PERIMETER
The
intimus 20000 S
produces a single focused magnetic pulse lasting less than 1/20 of a second.
The focused intensity allows the unit to erase today’s highest coercivity media while also limiting the
magnetic field exposure to 1 second for every 20 pieces of media degaussed.
Distance from
Degausser
Magnetic field
front side
Magnetic field
right side
Magnetic field
left side
Duration of Field
10 cm (4”)
610 gauss
75 gauss
198 gauss
< 0,05 Seconds
20 cm (8”)
191 gauss
36 gauss
77 gauss
< 0,05 Seconds
30 cm (12”)
88 gauss
33 gauss
35 gauss
< 0,05 Seconds
Note:
The testing room measured 0.4 gauss before degausser was plugged in.
Average Operational Distance (AOD) from user to the degausser is 12-18 inches (30-45cm). According
to the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values
(2005) - Static Magnetic Fields, whole body exposure limits recommended for an 8 hour shift are
600 gauss. Because of the short duration of each pulse from an degausser (1/20
th
* of a second) and
the extremely small magnetic field outside of the unit (<49 gauss, AOD) the total 8 hour whole body
exposure is 0,008% of the recommended limit.
* Pulse duration was rounded to ½ second per discharge for calculations to cover any build up of magnetic fields
generated before or after discharge.
INTRODUCTION
The degausser Model
intimus 20000 S
is a con-
tinuous duty capacitive discharge degausser.
The unit is designed to erase hard drives and
tape cartridges that fit inside the drawer. The
convenient media loading design accommo-
dates many different types and sizes of media,
without the need for adapters.
INSPECTION
Inspect the degausser for shipping damage as
soon as it is unpacked. If the degausser or any
accessories are damaged or fail to operate cor
-
rectly, notify carrier and contact your dealer im
-
mediately.
INSTALLATION
Power Plug
Plug the IEC connector attached to the power
cord supplied into the receptacle on the back of
the unit.
Location
The degausser must be placed on a flat, hard
surface. Keep at least a 15 cm (6 inch) distance
from any object that may interfere with the coo
-
ling fan exhaust located on the backside of the
degausser. As a general rule, media not inten-
ding to be erased should be kept about 60 cm
(2 ft) away.
Cooling
Forced air-cooling is used to maintain safe ope
-
rating temperatures within the degausser. The
air intake and exhaust through the holesis are
located on the back panel. To ensure proper
cooling, do not block the air-intake and maintain
at least a 15 cm (6“) distance from the back of
the degausser to any obstacle.
The machine may not be operated by more than
one person at any given time!
The machine was designed for safe operation
by “one person only”.
Persons with pacemakers must not work at the
unit before having consulted their attending doc
-
tor or physiotherapist!
Danger of heart rhythm
disturbances due to stray magnetic fields!
During the degaussing process no other work
may be performed on the machine (for example
cleaning, etc.)!
In case of danger switch the machine off with
the mains switch, or with the emergency switch,
or unplug the unit!
The unit is not a toy, and is
not suitable for use
by children!
The overall technical safety concept of this
machine does not provide for any guarantee
regarding hazard-free operation by children.
Always unplug the machine from the mains power
supply before opening the machine! Repairs
may only be performed by trained personnel!
Summary of Contents for 20000 S