Intex ECO15220-2 Owner'S Manual Download Page 17

345A

SAVE THESE INSTRUCTIONS

(345IO)  SAND FILTER PUMP COMBO  ENGLISH  7.5” X 10.3”  PANTONE 295U  07/10/2019

English

Page 17

Initial startup and operation:

Before operating, be sure that:

  •  All the hoses have been connected and tightened securely, and correct amount of filter sand 

    have been loaded.

  •  The entire system is connected to a grounding type receptacle protected by a ground-fault 

    circuit interrupter (GFCI) or residual current device (RCD). 

OPERATING INSTRUCTIONS (continued

)

CAUTION

The filter control valve has a closed position. The pump should never 

be on when the valve is in the closed position. If the pump is operated 

with the valve closed, explosive situation could exist.  

1.

  Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valves to 

allow water to flow into the sand filter pump. With water flowing into sand filter pump, the water 

pressure will allow the air trapped inside to escape from the air release valves 

(19)

. When all the 

air has escaped water will flow out of the valves 

(19)

. When this occurs gently finger tighten the 

valves 

(19) 

in a clockwise direction. 

  

IMPORTANT: To prevent air lock, open the lower plunger valve (connected inlet hose) first 

and then the upper plunger valve (connected outlet hose). Open the air release valves, wait 

until water starts to flow out of the air release valves, close air release valves.

2. 

Ensure the drain/waste outlet on the 6-way valve is not covered and directed to a proper draining 

receptacle.

3.

 

BACKWASH

 - Ensure the pump is off, depress the 6-way valve 

and turn it to the “

BACKWASH

” position 

(

see drawings 29 & 34

)

.

  

IMPORTANT: To prevent damage to the 6-way valve, always 

depress the valve handle before turning. Always switch off 

pump before changing the 6-way valve position. 

4.

 

Press 

 to switch

 on the system, and then 

press 

 to set

 

    the operating TIMER hours (see “Operating the system under 

TIMER mode or manually” section for details). Water is circulating 

backward through the sand media and to waste/drain outlet. 

Backwash until a clear flow of water is observed in the waste/drain outlet or through the drain 

sediment window.

  

NOTE:

 If the LED display flashes “00”, the device is in stand-by mode and the pump will not 

operate. The initial backwash of the filter is recommended to remove any impurities or fine sand 

particles in the sand media.

5.

  Switch off the pump, change the 6-way valve to “RINSE” position 

(

see drawing 30

)

.

6.

  Switch on the pump and run the pump for about one minute to level out the sand bed after 

    backwashing the sand media.

7.

  Switch off the pump, change the 6-way valve to “FILTER” position 

(

see drawing 28

)

.

8.

  Switch on the pump. The system is now operating in the normal filtering mode. Run the pump

    until the desired pool water clearance is obtained and no more than 12 hours per day. For the 

initial startup, it is recommended setting the system to a longer TIMER operating hours or “FP” for 

the pump to operate continuously without the TIMER.

9. 

Record the initial pressure gauge reading when the filter media is clean.

  

NOTE:

 During initial setup of the system, it may be necessary to backwash frequently due to 

    unusual heavy dirt present in the water and sand. After that, as the filter removes dirt and 

    impurities from the pool water, the accumulated dirt in the sand media will cause the pressure 

    to rise and the flow to diminish. If there is no vacuuming device attached to the system and 

    the pressure gauge reading is in the yellow zone it is time to backwash the sand media, see 

    “BACKWASH” under “initial startup and operation” section.

    Vacuuming device (i.e. Intex auto pool cleaner) attached to the system may also cause the 

    flow to diminish and the pressure to rise. Remove any vacuuming device from the system and 

    check if the pressure gauge reading has dropped from the yellow zone to the green zone.

10. 

Monitor the pressure gauge reading, and check that the inlet and outlet openings are not 

obstructed on a weekly basis. If the pressure gauge indicates yellow it is time to backwash the 

filter media.

34

1

2

Summary of Contents for ECO15220-2

Page 1: ...nd appearance which may result in updates to the instruction manual without notice 2019 Intex Marketing Ltd Intex Development Co Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todo...

Page 2: ...ons 16 20 LED Code Chart 21 Salt Pool Water Volumes 22 Intex Pools Salt Table 23 Intex Pools Cyanuric Acid Table 24 Intex Pools Operating Time Table 25 Non Intex Pools Salt Table 26 Non Intex Pools Cy...

Page 3: ...k do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standin...

Page 4: ...miliar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale These parts are not included if this pump was not purchased as part of a pool set Contact our...

Page 5: ...lat Strainer Rubber Washer 2 10255 10255 26 Threaded Strainer Connector 1 10744 10744 27 ADJUSTABLE POOL INLET JET NOZZLE 1 12369 12369 28 ADAPTOR B 2 10722 10722 29 STRAINER CONNECTOR 1 11070 11070 3...

Page 6: ...nger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 26 into one of the pre cut holes with the washer remaining on the connector to be placed a...

Page 7: ...threads with a petroleum jelly Then with the flat side of the strainer nut 24 facing the outside wall of the liner in a clockwise motion screw the strainer nut 24 back onto the inlet threaded air conn...

Page 8: ...arefully and inspect for any visible damage 2 In a counter clockwise motion unscrew the leaf trap cover 14 from the pre filter housing Take out the basket 16 and filter housing nut 17 see drawing 10 3...

Page 9: ...Ensure the pre filter housing water inlet hose connection is facing towards the pool IMPORTANT Some countries especially in the European community require the product to be secured to the ground or to...

Page 10: ...top of the center pipe Pour the sand into the tank at a slow rate see drawing 15 2 Fill the tank approximately half way remove the sand shield 6 from the top see drawing 16 3 Evenly distribute the sa...

Page 11: ...ve ensure the outlet connection from filter to the pool on the valve is facing towards the pool and the inlet connection from motor to valve is aligned with the motor outlet see drawing 20 SETUP INSTR...

Page 12: ...e electrodes line cords to the respective electrodes 48 49 tighten the plugs collars and electrodes cell housing collars by hand see drawing 25 4 Place an L shape o ring 11 on the cell housing inlet a...

Page 13: ...m the pool Position this product away from the pool so as to prevent children from climbing on it and accessing the pool Illustration Not to Scale According to the International Standard IEC 60364 7 7...

Page 14: ...glish Page 14 sand Filter Pump Hose Connection SetUp continued For INTEX pool with 1 1 4 32mm connections hoses Make sure the air jet valve 41 is securely tighten onto the pool inlet air adaptor 43 an...

Page 15: ...MBO ENGLISH 7 5 X 10 3 PANTONE 295U 07 10 2019 English Page 15 sand Filter Pump Hose Connection SetUp continued For NON INTEX pool Connect the hose 12 to the pool inlet outlet connection with a large...

Page 16: ...ct without water flowing through the system can cause a build up of hazardous pressure which can result in an explosive situation serious injury property damage or death Never test this pump with comp...

Page 17: ...details Water is circulating backward through the sand media and to waste drain outlet Backwash until a clear flow of water is observed in the waste drain outlet or through the drain sediment window...

Page 18: ...me time each day for the number of hours you have set 3 Lock keypad controls With the desired hour value showing press to lock the keypad controls which prevents unauthorized changing of the operating...

Page 19: ...selected too many hours keep pressing to repeat the cycle The built in timer will now activate your chlorinator at the same time each day for the number of hours you have set 2 With the desired hour v...

Page 20: ...ator the LED will always display the remaining operating hours of the pump You need to unlock the keypad and press button to review the programmed boost operating hours 4 To cancel the boost cycle pre...

Page 21: ...ning 05 Operating Hours 5 hours remaining 06 Operating Hours 6 hours remaining 07 Operating Hours 7 hours remaining 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operati...

Page 22: ...displays FP The unit is now in a Filter pump working mode to start the water circulation 2 Keep the Saltwater System turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly sprea...

Page 23: ...457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 160 75 40 20 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24 x 52 73...

Page 24: ...5 16 x 52 488cm x 132cm 4614 17464 1 2 0 5 18 x 42 549cm x 107cm 4786 18115 1 2 0 5 1 2 0 5 18 x 48 549cm x 122cm 5455 20647 1 4 0 6 1 4 0 6 CIRCULAR METAL FRAME POOL 15 x 36 457cm x 91cm 3282 12422...

Page 25: ...457cm x 91cm 3282 12422 2 3 4 15 x 42 457cm x 107cm 3861 14614 3 3 4 15 x 48 457cm x 122cm 4440 16805 3 4 5 16 x 48 488cm x 122cm 5061 19156 4 4 5 18 x 48 549cm x 122cm 6423 24311 3 3 4 5 5 6 21 x 52...

Page 26: ...150 65 40 20 40 20 8000 30000 200 90 55 25 8500 32000 210 95 55 25 10000 37500 250 110 70 30 12000 45500 300 135 80 35 14000 53000 350 160 95 45 OPERATING TIME TABLE for common Non Intex Pools Water...

Page 27: ...of the pre filter housing see drawing 35 4 In a counter clockwise motion unscrew the leaf trap cover 14 then remove the basket 16 and leaf trap o ring 15 from the pre filter housing see drawing 36 5...

Page 28: ...w the titanium electrode plug collar and cell collar disconnect the plug from the titanium electrode 48 and remove the titanium electrode from the cell housing see drawing 39 4 Place the titanium elec...

Page 29: ...the chlorine concentration at 0 5 3 ppm Directions and Use 1 Dip the entire strip into the water and remove immediately 2 Hold the strip level for 15 seconds Do not shake excess water from the strip 3...

Page 30: ...in pool water Combined Chlorine Is formed by the reaction of free chlorine with ammonia wastes Result if too high Sharp chlorinous odor eye irritation pH A value that indicates how acidic or basic a s...

Page 31: ...led between 0 degrees Celsius 32 degrees Fahrenheit and 40 degrees Celsius 104 degrees Fahrenheit 12 Cover the tank with a tarpaulin or plastic sheet to protect it from the weather Pool Care Chemicals...

Page 32: ...ve Contact Intex service center Use only No 20 silica sand with particle size range 0 45 to 0 85 mm 0 018 to 0 033 inches and a Uniformity Coefficient less than 1 75 Change sand Tighten or reinstall p...

Page 33: ...elease all trapped air in the circulation line Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the titanium electrode See Titanium E C...

Page 34: ...lorine Water is cloudy or milky Level is lower than on previous day Dirt or sand on pool floor Leaves insects etc Water recreation is both fun and therapeutic However it involves inherent risks of inj...

Page 35: ...he Service Center will inspect the item and determine the validity of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparab...

Reviews: