345A
SAVE THESE INSTRUCTIONS
(345IO) SAND FILTER PUMP COMBO ENGLISH 7.5” X 10.3” PANTONE 295U 07/10/2019
English
Page 28
TITANIUM AND E.C.O. ELECTRODES CLEANING
38
37
40
12
39
42
43
41
44
46
13
The titanium electrode and E.C.O. electrodes have
a self cleaning function incorporated into the
electronic control’s programming. In most cases this self cleaning action will keep the electrodes
working at optimum efficiency.
If the pool water is hard (high mineral content) the electrodes may
require periodic manual cleaning. To maintain maximum performance, we recommend that you
open and visually inspect the titanium and E.C.O. electrodes
(48 & 49)
monthly.
The following steps are some instructions on how to clean your cell.
1.
Switch off the unit
and
unplug the power cord from the electrical socket.
2.
Disconnect
the hose
(12)
from the cell housing
(46)
outlet
(see drawing 38)
.
3.
Unscrew
the titanium electrode plug collar and cell collar, disconnect the plug from the
titanium electrode
(48)
and remove the titanium electrode from the cell housing
(see
drawing 39)
.
4.
Place
the titanium electrode in a container and pour kitchen grade vinegar into the container
until the titanium electrode is immersed
(see drawing 40)
.
Soak for 1 hour and then flush
with a high-pressure garden hose.
5.
Unscrew
the E.C.O. electrode plug collar and cell collar, disconnect the plug from the E.C.O.
electrode
(49)
and remove the E.C.O. electrode from the cell housing
(see drawing 41)
.
6.
Place
the E.C.O. electrode in a container and pour kitchen grade vinegar into the container
until the E.C.O. electrode is immersed
(see drawing 42)
.
Soak for 1 hour and then flush with
a high-pressure garden hose.
7.
Disconnect
the interconnecting hose
(13)
from the cell housing inlet
(see drawings 37 &
43)
.
8.
Remove
the cell housing from the tank base
(see drawing 44)
.
9.
F
lush with
a high-pressure garden hose if there is any sediments in the cell housing.
10.
Reverse
steps 2 to 9 to reconnect everything back.