TROUBLESHOOTING GUIDE (continued)
1.
Circulation line is blocked.
2
. Incorrect inlet and outlet hose
direction.
3
.
Scale on flow sensor pins inside the
titanium electrode.
4
.
Titanium electrode cord is loose.
5
. Device is set and operating in
backwash, rinse or waste mode.
6
.
Titanium electrode failure.
1
. Dirt or scale on titanium
electrode
plates.
2
. Low salt level / No salt.
3
.
Titanium electrode cord is loose.
4
. Possible electrolytic cell failure.
1
. High salt level.
2
. Water Temperature > 35ºC.
3
. Titanium electrode failure.
1
. LED display is off and the “SERVICE”
light is on - the system does not power
up.
2
.
Control station failure.
1
.
The LED display shows a red dot only and
unit does not respond - the electrodes(s)
is/are short circuited.
2
.
Control station failure.
•
If your unit has plunger valves, ensure that
they are open.
•
Clear the basket and cell housing from debris
and dirt.
See “Maintenance” section.
•
Depress the 6-way valve, release all trapped
air in the circulation line.
•
Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See
“Set Up Instructions”.
•
Clean the titanium electrode.
See “Titanium &
E.C.O. Electrodes Cleaning” section.
•
Plug the cord into the titanium electrode and
tighten the plug collar firmly.
•
Ignore the alarm, finish the backwash, rinse
or waste operation then turn the power switch
OFF and ON again to reset the alarm.
•
Contact Intex Service Center.
•
Remove the titanium electrode for inspection.
Clean it if necessary.
See “Titanium & E.C.O.
Electrodes Cleaning” section.
•
Add salt. See “Salt & Pool Water Volumes”.
•
Plug the cord into the titanium electrode and
tighten the plug collar firmly.
•
Contact Intex Service Center. Replace the
cell if needed.
•
Partially drain the pool and refill it with fresh
water. See “Salt & Pool Water Volumes”.
•
Contact Intex Service Center.
•
Household voltage is too high or too low (+ 20%).
Check the voltage is within the range stated on the
device housing.
•
Contact Intex Service Center.
• Remove and clean the electrode(s). Replace the
electrode(s) if needed.
• Contact Intex Service Center.
LED PANEL
CODE
PROBLEM
SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).