SEPAMAT F-SC_Manual_Vers.1.0e_en
28
Description
Cause
Solution
Pump runs continuously
with a low flow rate or turns
on without use from the
consumer
a.) Unsealed, leaking fixture
b.) Too little water demand from
the fixture (<1 l/min)
c.) Selected operating pressure
is too high
d.) Settings changed or a
malfunction
a.) Repair leak
b.) Check fixtures
c.) Reduce operating pressure (3
bar is optimal)
d.) RESET and perform a new
self-initialization (STOP, then
START)
Flow rate too low or no
water is supplied by pump
Too little or no water is in the
separation chamber
Check mains water pressure,
clean the filter sieve in the mains
water valve
(see section 5.4)
10. Maintenance
The SMT
F-SC
operates without regular maintenance.
At minimum, check the correct priming pressure in the expansion vessel of 2 bar every year.
11. Spare parts
Description
Figure no.
(see section
4.1)
Order code
Multistage centrifugal pump SEPAMAT F-SC
20
[1]
RMF-SC-P20
Multistage centrifugal pump SEPAMAT F-SC
40
[1]
RMF-SC-P40
Basic controller
[2]
RMF-SC-BPL
Pump controller SC incl. pressure switch
[5]
RMF-SC-PST
Pressure switch 4-20 mA
[6]
RMF-SC-DS
Separation chamber
[7]
RMF-B
Floating valve for separation chamber
[9]
RMF-NSP
Spare parts for centrifugal pumps
See section
5.3
See section 5.3