SEPAMAT F-SC_Manual_Vers.1.0e_en
15
Code
LED-
Display
Function
Description
Range
Default
setting
F1
Minimum
flow rate stop
Setting of the minimum flow
rate level
10...+10
Each step: 1
0
F2
Maximum
motor current
Setting of the maximum
motor current
SMT-F-SC20: 3.0 A
SMT-F-SC40: 3.5 A
1...7 A
Each step: 0.5
A
7 A
F3
Minimum
motor speed
Setting of the minimum
motor speed (Reference of
the nominal speed is
2850 min
-1
)
30..70%
Each step: 2%
50%
F4
Maximum
motor speed
Setting of the maximum
motor speed (Reference of
the nominal velocity is 2850
min
-1
)
90..110%
Each step: 1%
105%
F5
Rotation
direction
0/1
0/1
0
F6
Starting
RPM ramp-up
RPM during acceleration
1000-10000
RPM/s
Each step: 500
3000
RPM/s
F7
Maximum
operating
pressure
Maximum system pressure
that should not be
exceeded
2 ...10 bar
Each step:
0.5 bar
10 bar
F8
Pressure
hysteresis
Setting of the maximum
pressure hysteresis
(difference between switch
point and reset point)
0.15 ..1 bar
Each step: 0.05
bar
0.3 bar
F9
Pressure
ramp-up
Setting for the rate of
pressure increase or
decrease
0.1 … 2 bar/s
Each step:
0.1 bar/s
1 bar/s
F10
Pressure sensor
minimum output
signal
Setting for the minimum
output signal from the
pressure sensor
1..5 mA
Each step:
0.2 mA
4 mA
F11
Pressure sensor
maximum output
signal
Setting for the maximum
output signal from the
pressure sensor
10.. 20 mA
Each step:
0.5 mA
20 mA