background image

 
 

 
 

 

  

13

 

 
 

2.

 

Spare

 

parts

 

 

Article

 

description

 

Article

  

Art.

 

No.

 

AQUALOOP

 

controller

 

ALMS

CU

  

600700

 

AQUALOOP

 

AC

 

switching

 

power

 

supply

 

24

 

V

 

DC,

 

4A

 

ALMS

N

4A

 

EU

 

600701

 

AQUALOOP

 

floating

 

switch,

 

3

 

m

 

ALMS

SCHW3m

 

600702

 

AQUALOOP

 

pump

 

module

 

for

 

membrane

 

station

 

ALMS

PVers.0.1

 

600703

 

AQUALOOP

 

membrane

 

incl.

 

PVC

 

connection

 

elbows

 

AL

MEM

 

230010

 

AQUALOOP

 

membrane

 

seal

 

set

 

ALMEM

SEAL

 

600715

 

AQUALOOP

 

growth

 

bodies

 

30

 

L

 

AL

FK30

 

230025

 

AQUALOOP

 

citric

 

acid

 

concentrate

 

70

 

mL

 

AL

Acid70

 

230040

 

AQUALOOP

 

citric

 

acid

 

concentrate

 

420

 

mL

 

AL

Acid420

 

230045

 

AQUALOOP

 

chlorine

 

concentrate

 

110

 

mL

 

AL

Chlor110

 

230050

 

AQUALOOP

 

chlorine

 

concentrate

 

660

 

mL

 

AL

Chlor660

 

230055

 

AQUALOOP

 

blower

 

filter

 

element

 

for

 

30,

 

100,

 

120

 

Note:

 

100

 

and

 

120

 

needs

 

two

 

elements

 

ALBL

FILTER

A

 

 

600716

 

 

AQUALOOP

 

blower

 

filter

 

element

 

for

 

60,

 

200

 

Note:

 

200

 

needs

 

two

 

elements

 

ALBL

FILTER

B

 

 

600717

 

 

AQUALOOP

 

blower

 

repair

 

kit

 

for

 

30

 

ALBL

KIT030

 

600718

 

AQUALOOP

 

blower

 

repair

 

kit

 

for

 

60

 

ALBL

KIT060

 

600719

 

AQUALOOP

 

blower

 

repair

 

kit

 

for

 

100

 

and

 

120

 

ALBL

KIT100/120

 

600720

 

AQUALOOP

 

blower

 

repair

 

kit

 

for

 

200

 

ALBL

KIT200

 

600721

 

Spare

 

parts

 

can

 

be

 

ordered

 

directly

 

from

 

INTEWA

 

GmbH

 

or

 

please

 

ask

 

your

 

local

 

dealer.

  

 

 
 

3.

 

Optional

 

accessories

 

 

Article:

   

AL

PCS

 

AQUALOOP

 

Pressure

 

sensor

 

for

 

monitoring

 

pump

 

performance

 

Measuring

 

range:

   ‐

0.8

 

to

 

+0.8

 

bar,

 

Connection:

  

4

20

 

mA,

 

ventilated

 

3

 

line

 

terminals

 

Cable:

 

Ø6mm,

 

3

 

m

 

length

 

 

 

 

 

Article:

   

AL

TANK

 

60L

 

AQUALOOP

 

tank

 

60

 

Litres

 

Suitable

 

for

 

external

 

cleaning

 

of

 

one

 

single

 

membrane

 

station

 

 

Tank

 

volume:

  

60

 

Litres

 

Dimensions:

  

Ø

 

164

 

x

 

486

 

mm

  

 
 

   

 

Summary of Contents for AQUALOOP greywater recycling 1200 L/day

Page 1: ...reywater recycling 300 L day AQUALOOP greywater recycling 600 L day AQUALOOP greywater recycling 900 L day AQUALOOP greywater recycling 1200 L day AQUALOOP greywater recycling 1500 L day AQUALOOP grey...

Page 2: ...Pressure sensor 4 1 5 Blower 4 1 6 1 Mechanical cleaning of the membrane 5 1 6 2 Chemical cleaning 6 1 6 2 1 In situ cleaning in the bioreactor 6 1 6 2 2 Intensive cleaning in separate cleaning tank...

Page 3: ...onding chapters Maintenance and or check interval Replacement interval Pre filter Check and clean every 3 months Filtration backwash pump Check every 6 months Replace after 20 000 hrs running time Flo...

Page 4: ...d It is suggested that the filtration and backwash pump set be replaced after 20 000 hrs running time Please rerun the water tightness test to ensure there are no air leaks in the pipework after the r...

Page 5: ...the menu overview every 6 months Menu 5 Status 2 Pressure sensor pumps P ADr Pressure sensor blower P ADg When the pressure sensor is not connected the pressure displays 1 200 bar 1 5 Blower AQUALOOP...

Page 6: ...ich is included with the blowers 1 6 Membrane 1 6 1 Mechanical cleaning of the membrane It needs to be determined based on the amount of sludge present in the bottom of the bioreactor whether a full e...

Page 7: ...e In Situ cleaning Intensive cleaning Cleaning time 2 hrs 12 24 hrs Cleaning result greywater application Depends on the initial state of the membrane up to 1 5 L min Independent of the initial state...

Page 8: ...in1 BRmin1 Fig Cleaning connection during normal operation Fig Cleaning device with connected canister chem fluid Shut off valve V1 open Shut off valve V1 close Shut off valve V2 close Shut off valve...

Page 9: ...tion s section 11 6 3 can be added through the cleaning connection In small tank systems with good accessibility e g AL GW200 the cleaning solution can be filled directly into the backwash tank Note T...

Page 10: ...in the standard manner The goal is to circulate the cleaning solution under normal pressure and flow rate for 24 hours Therefore the start times T1 and T2 and filtration cycles have to be set as foll...

Page 11: ...tion with integrated control unit 1 6 2 3 Cleaning solution We recommend the cleaning solution to be made from regular domestic cleaning agents and should be mixed as following example for In Situ cle...

Page 12: ...d well with water after being cleaned with acid before cleaning with alkali and the other way around Follow the warning and safety instructions of the chemicals used Protective gloves and glasses are...

Page 13: ...dissolved oxygen content should be 4 mg L with a range up to 8 mg L The AQUALOOP system treated outflow should be clear like tap water If the effluent is not clear please check the tightness of all me...

Page 14: ...OP blower filter element for 30 100 120 Note 100 and 120 needs two elements ALBL FILTER A 600716 AQUALOOP blower filter element for 60 200 Note 200 needs two elements ALBL FILTER B 600717 AQUALOOP blo...

Page 15: ...djusted Voltage 24 V DC Power 12 W 4 Warranty Contact The warranty terms are included in our sales conditions and can be viewed at http www intewa de en customer menu contact legal conditions For any...

Page 16: ...direct or consequential damages including but not limited to lost profits lost income labour charges delays in production and or idle production which result from defects in material and or workmansh...

Page 17: ...from notification Owner Requirements 1 AQUALOOP system owners must sign a service contract with a local dealer to conduct periodic checks and maintenance and comply with all requirements outlines in I...

Page 18: ...y http www intewa de en company partners international distributors Distribution in South Africa is handled by Pure Rain Technologies Pty Ltd Cirtech House Westlake Business Park Cape Town Tel 086 111...

Page 19: ...18 INTEWA GmbH Version v2 0 sa Subject to technical changes...

Reviews: