3. Connection and placement
3.1 Connection to AC unit
Disconnect mains power from the AC unit. Open the front cover of the indoor unit in order
to have access to the internal control board. In the control board locate the socket
connector marked as:
CN-CNT
in Domestic line models
Using the cable that comes with the IntesisBox
®
, insert one of its connectors, the biggest
one, into the socket of the IntesisBox
®
, and the other connector, the one installed in the
largest uncovered part, to the socket
CN-CNT
of the AC unit's electronic circuit. Close the
AC indoor unit's front cover again.
Figure 3.1
IntesisBox
®
connection diagram
Important
: Do not modify the length of the cable supplied with the interface, it may
affect to the correct operation of the interface
To connect the IntesisBox
®
to the AC, use the lid hole above the connector K1 as indicated
in Figure 3.2:
Figure 3.2
Connection scheme
Important:
The cable should not be placed on top of the antenna zone (is marked in Figure
3.2) as the performance of the device might be affected. The antenna zone changes
depending on the position of the antenna cable (see section 8.9).
40 mm
CN-CNT
IntesisBox
®
Insert the cable through
the hole and follow the
instructions below
AC indoor unit
Electronic
circuit board
Connection cable
supplied with the
interface.
200 mm
Lid holes
Wall fixing holes
Antenna zone