background image

  11 / 18 

  Remote Control Storage Area 

 

z

  If the air conditioner will not be used for an extended period of time, remove the batteries from the remote 

control. 

4.  Remote Control Storage 

Your  air  conditioner  has  a  special  place  for  remote  control  storage.  Please  always  put  remote  control  into 

compartment after use.     

Note: In order to avoid losing the remote control, please put the remote control inside of the storage place when 

you do not use it. 

 

CAUTION

 

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water, do not use the remote 

control if the batteries have any leakage. 

If you eat the liquid from the batteries, brush your teeth and see doctor. The chemicals in batteries could cause 

burns or other health hazards. 

 

 

Multiple Protection Functions 

1.  Anti-freeze protection function

 

Compressor, water spraying motor will turn off when compressors running over 10 minutes and tube temperature 

(Tp)  is  continuously 

2

 for 20  seconds under cooling mode, E4 will show  on LED display window,  the unit 

initiates the anti-frost protection and all buttons on control panel (except for power button) are inactive.   

Once the tube temperature 

8

, the protection is relieved to recover into original status, and compressor apply 

to 3-minute delay protection. 

2.  Water-full safety alarm and shut 

off protection function:   

Warning sounds when the water volume reached its alarm level in water tank, and unit is automatically stop 

working, both water-full indicator and 

FL

 on LED window is flashing. You need to drain the condensate for unit to 

automatically recover operation. (For more information about how to drain, 

refer to the “

Drainage Instruction

 

please). 

3.  Delay protection function of compressor 

This unit offers restart protection to compressor. Except that the compressor may start immediately when the unit 

is energized at first time, there is 3-minute start delay after compressor is shut down. 

 

Handling and Transportation 

1.  Handle and move the unit 

Hold the top of the air outlet window in front panel with one hand and the handle at the top of back panel with another 

hand, then move the unit in upright position (As shown in Photo below). 

Note:   

z

  Do not hold the horizontal louvers by hand. 

z

  Make the unit in the upright position whatever handling or moving it. 

Summary of Contents for DELLA

Page 1: ...ual Part Number 048 GM 48266 Thank you very much for selecting this new model of Portable Air Conditioner please read this Use and Care Manual carefully before installing and using this appliance Plea...

Page 2: ...hnical Specification 5 Features and Identification of Parts 6 Operation and Settings 8 Protection 12 Handling and Transportation 12 Installation and Adjustment 13 Drainage Instruction 16 Maintenance a...

Page 3: ...electrical shock or injury when using your air conditioner follow up these basic precautions Indoor use only it is prohibited to use this unit outdoors or in humid environment such as bathroom etc Do...

Page 4: ...ns see Installation and Adjustment Keep the drain hose in good condition without flexure then connect with unit Manually adjust the vertical and horizontal louvers slightly to protect louvers from any...

Page 5: ...accessible by panel control and remote control Temperature setting range of this unit is 17 30 62 86 This unit is designed with various protection functions such as 24 hour programmable timer auto co...

Page 6: ...d winding pillar and universal plug fixing holes can well protect the power cord High position of exhaust air outlet easy assembly and exhaust venting quickly 24 hour Timer function unique on off remi...

Page 7: ...aust hose adapter 25 Window seal plate assembly Operation and Settings 1 Control Panel This section explains proper mobile air conditioner operation Figure 3 On Off button Mode button Up button Timer...

Page 8: ...o convert Celsius degrees and Fahrenheit degrees and corresponding indicator will light up 4 Adjust fan speed Press the button to select a desired fan speed shown below 5 Stand by Press the button aga...

Page 9: ...room temperature is shown on LED display window z Press Timer button to set automatic ON time while unit is off will light up z The unit will turn on automatically and working at original mode when th...

Page 10: ...ect Cool mode Button press this button to select Fan mode Button press this button to select Dry or dehumidifying mode Button press this button to select Sleep function under cooling mode Before using...

Page 11: ...e anti frost protection and all buttons on control panel except for power button are inactive Once the tube temperature 8 the protection is relieved to recover into original status and compressor appl...

Page 12: ...bly and its adapter 1 Take out the exhaust hose assembly and its adapter from plastic bag 2 Extend the exhaust hose at one end screw the round end of adapter into exhaust hose at anticlockwise directi...

Page 13: ...emarks z Keep the right direction of slant side A of adapter for ease installation of window seal plate z Keep exhaust hose assembly be strongly locked by fasteners in exhaust outlet to avoid its fall...

Page 14: ...se adapter and set them together then slide adapter downwards to make 2 set of openings locked for 2 parts good connection B Lock self tapping screw 4mm into adapter hole Remarks z Slide the adapter d...

Page 15: ...efore the tray is full if it can t hold all water in the unit to prevent the water leakage and wet the floor or carpet l Water stopper and drain cover must be tightly installed to avoid new condensate...

Page 16: ...e to take out the filter to avoid any twist or damage to filter z Take out filters of back panel at first then side panel 2 Clean the filters gently in warm water about 40 mixed with detergent and dry...

Page 17: ...before asking for professional service but never dismantle or repair the unit by yourself it may cause harm to you and your property Trouble Cause Remedy The unit fails to start up Power supply failu...

Page 18: ...arameters Model FSD or 50F Voltage 250V Current 3 15A Schematic diagram of the air conditioner For specific technical parameters of the model refer to rating label on the product Correct Disposal of t...

Reviews: