  15 / 18 

air-conditioner. The exhaust hose must be smooth or it may lead air-conditioner overheat and trip because exhaust 

hose is obstructed. 

 

Drainage Instruction 

1.  Manual drain:   

When  the  water  volume  reached  its  alarm  level  in  water  tank,  warning  sounds  and  unit  is  automatically  stop 

working, both water-full indicator and “FL” is flashing on LED display window. 

1)  Put the tray below the water outlet at the back of the unit. 

2)  Screw off the drain cover, unplug the water stopper for water flow into the tray. 

3)  Plug in stopper and screw the water cover tightly onto water outlet after drainage. 

Notes:   

l

  Protect the drain cover and water stopper properly. 

l

  Move the unit carefully to avoid the leakage if it is necessary. 

l

  Tilt the unit slightly backwards when draining. 

l

  Block the drain hole as soon as possible before the tray is full if it can’t hold all water in the unit to prevent the 

water leakage and wet the floor or carpet. 

l

  Water stopper and drain cover must be tightly installed, to avoid new condensate to wet the floor or carpet when 

the unit re-starts working.   

 

 

 

 

 

 

 

 

2. Continuous drain: 

1)  Screw off the drain cover and unplug the water stopper (as Photo). 

2)  Connect drain-hole with 

φ

13mm PVC drain hose, as deep as possible to avoid leakage (as Photo). 

3)  Pull the drain hose to bathroom or outdoor. 

Notes:     

l

  Drain hose must be installed before unit starts working.   

l

  It is suggested to use manual drainage when unit in cooling mode, to ensure enough water to recycle in the unit 

to cool condenser and enhance cooling performance.   

l

  Put the drain hose in an inaccessible place, not higher than drainage hole and keep drain hose straight without 

any flexure. 

l

  Keep the drain cover and its stopper properly installed when continuous drainage is adopted. 

 

 

 

 

 

 

 

 

 

 

Drain Cover 

Water Stopper 

Drainage Hole 

Drain cap 

Water Stopper 

Drain Hole 

Summary of Contents for DELLA

Page 1: ...ual Part Number 048 GM 48266 Thank you very much for selecting this new model of Portable Air Conditioner please read this Use and Care Manual carefully before installing and using this appliance Plea...

Page 2: ...hnical Specification 5 Features and Identification of Parts 6 Operation and Settings 8 Protection 12 Handling and Transportation 12 Installation and Adjustment 13 Drainage Instruction 16 Maintenance a...

Page 3: ...electrical shock or injury when using your air conditioner follow up these basic precautions Indoor use only it is prohibited to use this unit outdoors or in humid environment such as bathroom etc Do...

Page 4: ...ns see Installation and Adjustment Keep the drain hose in good condition without flexure then connect with unit Manually adjust the vertical and horizontal louvers slightly to protect louvers from any...

Page 5: ...accessible by panel control and remote control Temperature setting range of this unit is 17 30 62 86 This unit is designed with various protection functions such as 24 hour programmable timer auto co...

Page 6: ...d winding pillar and universal plug fixing holes can well protect the power cord High position of exhaust air outlet easy assembly and exhaust venting quickly 24 hour Timer function unique on off remi...

Page 7: ...aust hose adapter 25 Window seal plate assembly Operation and Settings 1 Control Panel This section explains proper mobile air conditioner operation Figure 3 On Off button Mode button Up button Timer...

Page 8: ...o convert Celsius degrees and Fahrenheit degrees and corresponding indicator will light up 4 Adjust fan speed Press the button to select a desired fan speed shown below 5 Stand by Press the button aga...

Page 9: ...room temperature is shown on LED display window z Press Timer button to set automatic ON time while unit is off will light up z The unit will turn on automatically and working at original mode when th...

Page 10: ...ect Cool mode Button press this button to select Fan mode Button press this button to select Dry or dehumidifying mode Button press this button to select Sleep function under cooling mode Before using...

Page 11: ...e anti frost protection and all buttons on control panel except for power button are inactive Once the tube temperature 8 the protection is relieved to recover into original status and compressor appl...

Page 12: ...bly and its adapter 1 Take out the exhaust hose assembly and its adapter from plastic bag 2 Extend the exhaust hose at one end screw the round end of adapter into exhaust hose at anticlockwise directi...

Page 13: ...emarks z Keep the right direction of slant side A of adapter for ease installation of window seal plate z Keep exhaust hose assembly be strongly locked by fasteners in exhaust outlet to avoid its fall...

Page 14: ...se adapter and set them together then slide adapter downwards to make 2 set of openings locked for 2 parts good connection B Lock self tapping screw 4mm into adapter hole Remarks z Slide the adapter d...

Page 15: ...efore the tray is full if it can t hold all water in the unit to prevent the water leakage and wet the floor or carpet l Water stopper and drain cover must be tightly installed to avoid new condensate...

Page 16: ...e to take out the filter to avoid any twist or damage to filter z Take out filters of back panel at first then side panel 2 Clean the filters gently in warm water about 40 mixed with detergent and dry...

Page 17: ...before asking for professional service but never dismantle or repair the unit by yourself it may cause harm to you and your property Trouble Cause Remedy The unit fails to start up Power supply failu...

Page 18: ...arameters Model FSD or 50F Voltage 250V Current 3 15A Schematic diagram of the air conditioner For specific technical parameters of the model refer to rating label on the product Correct Disposal of t...

Reviews: