background image

www.intertec.info

Operating Instructions SL MINITHERM DNLA

HOM177850763Ien-7

Page 3 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

1

General

These  operating  instructions  describe  the  safe  and
proper  way  to  work  with  the  device.  The  safety
information  and  instructions  given  as  well  as  the  local
accident  prevention  regulations  and  general  safety
regulations  valid  in  the  area  of  application  must  be
complied  with.  These  instructions  are  a  constituent  part
of  the  instrument  and  need  to  be  kept  in  the  immediate
vicinity of the device accessible to personnel at all times.

Before  starting  any  work,  the  operating  instructions
should be read in full.

2

Use

The  electrical  heater  of  the  SL..THERM  series  is  used
for  direct  heating  through  flange-mounting  (conduction)
of for room heating (convection).

 WARNING

The heater is only designed for non hazardous
areas.

INTERTEC-Hess GmbH accepts no liability for improper
use.

The areas of application are:

• Frost protection

• Condensation protection

• Maintaining temperature

As  an  option,  thermostats  can  be  integrated  in  the
connecting  cable.  If  a  TAE  is  used,  the  respective
operating instructions must be complied with.

3

Explanation of symbols for warnings
and signal words

The  safety  information  warns  the  user  about  risks  and
provide information on how risks can be avoided.

Safety  information  can  be  found  at  the  start  of  the
chapter  before  the  instructions  which  may  lead  to  a
hazardous situation. Additional safety information can be
found at the beginning of this manual.

Safety  instructions  which  must  be  adhered  to  are
highlighted as follows:

 DANGER

DANGER

This sign is warning about an extremely hazardous
situation which, if not heeded, will lead to death or
serious irreversible injury.

 WARNING

WARNING

This sign is warning about a hazardous situation which,
if not heeded, may lead to death or serious irreversible
injury.

 CAUTION

NOTICE

This sign is warning about a hazardous situation which,
if not heeded, may lead to slight, reversible injury.

NOTICE

NOTE

It is essential to pay attention to this safety advice as you
may otherwise incur material damage.

 INFO

Important notes and useful additional information.

4

Safety information

 CAUTION

Risk of injury at the rib ends

The sharp edges on the heating ribs may cause injury if
handled incorrectly.

 CAUTION

Risk of burns from a hot surface

Attainable highest temperatures: Max. 160°C

Do not touch device during operation! Before working on
the device, allow it to cool down first.

Summary of Contents for SL MINITHERM DNLA

Page 1: ...Operating Instructions SL MINITHERM DNLA HOM177850763Ien 7 24 08 2021 ...

Page 2: ...f contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 6 10 Maintenance 6 11 Troubleshooting 7 12 Deinstallation 7 13 Disposal 7 14 EU declaration of conformity 7 15 Further information and service 7 ...

Page 3: ...e operating instructions must be complied with 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks and provide information on how risks can be avoided Safety information can be found at the start of the chapter before the instructions which may lead to a hazardous situation Additional safety information can be found at the beginning of this manu...

Page 4: ...e Failure 50 000 h Storage temperature 60 to 80 C Profile type L Length x Width x Height 109 x 211 x 40 mm Profile type L SF Length x Width x Height 109 x 127 x 40 mm INFO You will find the precise technical data for your instrument on the label You will find information on the heating output on the data sheet Rated output Rated voltage Operating voltage Thermostat Illustration 1 Example SL MINITH...

Page 5: ...ied on the nameplate Where operating voltage measured voltage rated voltage then the heater is at its rated output Mains voltage fluctuations up to 10 are then permissible Each heater with integrated TS thermostat must be preceded by a 10 A fuse or a motor protection switch with short circuit and thermal quick release set to 10 A as short circuit protection When using a heater without integrated t...

Page 6: ... with TAE 1 2 J L N PE J Junction box Heater TS Option AM bn bu ye gn bk gy bn brown bu blue ye gn yellow green bk black gy grey Illustration 6 SL THERM with TS 9 Commissioning If the heater is installed in accordance with the notes in the Installation Page 4 section and Connection Page 5 sections then the radiator may be commissioned CAUTION Sufficient heat dissipation must be ensured Unauthorize...

Page 7: ...cal labour protection and environmental regulations into consideration and make sure that the components are recycled Scrap metal Send plastic elements to recycling Sort other components according to their material properties and dispose of them NOTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment ...

Page 8: ...info intertec info Website www intertec info Warranty The legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for heating systems and accessories These instructions do not claim to take all designs options or changes into consideration even in association w...

Reviews: