background image

www.intertec.info

Operating Instructions SL MINITHERM DNLA

Page 8 / 8

HOM177850763Ien-7

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

Please  contact  your  INTERTEC  contact  person  or
directly contact

INTERTEC-Hess GmbH

Raffineriestr. 8

93333 Neustadt/Donau

Germany

Phone: +49 9445 9532-0

e-mail: [email protected]

Website: www.intertec.info

Warranty

The  legally  defined  warranties  and  warranty  periods  of
24  months  are  applicable  to  our  scope  of  supply  and
services.

You  will  find  more  detailed  information  in  the
manufacturer  warranty  from  INTERTEC  for  heating
systems and accessories.

These instructions do not claim to take all

designs, options or changes into

consideration, even in association with

installation, operation or maintenance.

INTERTEC does not accept responsibility

for providing information about changes

made retrospectively.

Summary of Contents for SL MINITHERM DNLA

Page 1: ...Operating Instructions SL MINITHERM DNLA HOM177850763Ien 7 24 08 2021 ...

Page 2: ...f contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 6 10 Maintenance 6 11 Troubleshooting 7 12 Deinstallation 7 13 Disposal 7 14 EU declaration of conformity 7 15 Further information and service 7 ...

Page 3: ...e operating instructions must be complied with 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks and provide information on how risks can be avoided Safety information can be found at the start of the chapter before the instructions which may lead to a hazardous situation Additional safety information can be found at the beginning of this manu...

Page 4: ...e Failure 50 000 h Storage temperature 60 to 80 C Profile type L Length x Width x Height 109 x 211 x 40 mm Profile type L SF Length x Width x Height 109 x 127 x 40 mm INFO You will find the precise technical data for your instrument on the label You will find information on the heating output on the data sheet Rated output Rated voltage Operating voltage Thermostat Illustration 1 Example SL MINITH...

Page 5: ...ied on the nameplate Where operating voltage measured voltage rated voltage then the heater is at its rated output Mains voltage fluctuations up to 10 are then permissible Each heater with integrated TS thermostat must be preceded by a 10 A fuse or a motor protection switch with short circuit and thermal quick release set to 10 A as short circuit protection When using a heater without integrated t...

Page 6: ... with TAE 1 2 J L N PE J Junction box Heater TS Option AM bn bu ye gn bk gy bn brown bu blue ye gn yellow green bk black gy grey Illustration 6 SL THERM with TS 9 Commissioning If the heater is installed in accordance with the notes in the Installation Page 4 section and Connection Page 5 sections then the radiator may be commissioned CAUTION Sufficient heat dissipation must be ensured Unauthorize...

Page 7: ...cal labour protection and environmental regulations into consideration and make sure that the components are recycled Scrap metal Send plastic elements to recycling Sort other components according to their material properties and dispose of them NOTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment ...

Page 8: ...info intertec info Website www intertec info Warranty The legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for heating systems and accessories These instructions do not claim to take all designs options or changes into consideration even in association w...

Reviews: