Leakage and function test
1.
If using the primary breathing valve with safety pressure lever, make sure
that the safety pressure lever is in closed position.
2.
Turn the reserve lever to reserve position.
3.
Open the cylinder valve slowly and observe the pressure gauge. Check
that the pointer moves normally and smoothly. If the pointer moves
irregularly or not at all, the pressure gauge is faulty. When the cylinder
valve is fully open, then close it a quarter turn.
Check that the reserve lever on the reserve valve flips up to dive position
when the pressure rises.
4.
Check the pressure gauge to make sure that there is enough air pressure
in the cylinder for the planned dive. Interspiro recommends that the
cylinder should be full before every dive.