Interroll Diverter SH 1500
Maintenance and repair
Version 1.0 (06/2022) en
Translation of original operating instructions
51
Preparatory and follow-up maintenance work
DANGER
Danger to life from electrocution and crushing
Installation and maintenance tasks on 400-V conveyor systems while they are in operation can
cause life-threatening electrocution and serious crushing.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Removing/installing the
side plates
2
1
4
3
3
1
4
2
Removing the side plates
1
Side frame
3
Torx screw
2
Washer
4
Side plate
Requirement:
R
The module is shut down.
4
Remove screws (2) and washers (3) on the right and left from the side plate (4) and take the
side plate off the side frame.
4
After the maintenance work: Fasten side plates (4) on the right and left with screws (2) and
washers (3) at the side frames (1).