Version 2.0 (12/2019) Online
Translation of the original operating manual
33 von 38
Appendix
10
Appendix
10.1
Replacing a RollerDrive EC200
The RollerDrive EC310 can also replace a RollerDrive EC200. In such a case, speed variations may occur. To
approximately achieve the desired speeds, different DIP switch settings are required than those used for the
replacement of the RollerDrive EC300.
Gear ratio
DIP switches
Nominal torque
[Nm]
Max. torque
[Nm]
Max. speed [m/s]
Speed
differenz
EC200
EC310
Bit 3
Bit 2
Bit 1
Bit 0
7,85:1
/ 13:1
EC200
EC310
EC200
EC310
EC200
EC310
12:1
16:1
OFF
OFF
ON
OFF
ON
0,70
0,81
1,20
1,95
0,98
0,92
-7 %
16:1
20:1
OFF
OFF
ON
OFF
ON
0,90
1,01
1,80
2,44
0,74
0,73
-1 %
36:1
48:1
OFF
OFF
ON
OFF
ON
1,70
2,42
3,60
5,85
0,33
0,31
-7 %
36:1E
20:1
OFF
OFF
OFF
OFF
OFF
1,30
1,01
2,60
2,44
0,44
0,40
-8 %
48:1
64:1
OFF
OFF
ON
OFF
ON
2,30
3,23
5,40
7,80
0,25
0,23
-7 %
64:1
96:1
OFF
OFF
ON
OFF
ON
3,60
4,84
8,00
11,69
0,18
0,15
-17 %
10.2
Electrical data of connectors
RollerDrive connector
Power supply (Pin 1, 3)
Nominal value
24 V DC
Voltage range
18 to 26 V DC
Residual ripple
max. 600 mV
PP
Rated current
0 to 2,3 A
Peak current
max. 5 A
max. 250 ms > 2.3 A,
time-dependent current flow
triangular, duty factor ≤ 19 %
Return electric strength
max. 35 V DC
absence of harmonic waves
max. 500 ms; after 500 ms the
reserve voltage must be 27 V,
duty factor max. 27 %