28 von 38
Version 2.0 (12/2019) Online
Translation of the original operating manual
Initial startup and operation
6
Initial startup and operation
6.1
Commissioning
Pre-commissioning checks
¾
Ensure that the AdControl has been correctly fastened to the profile and that all screws have been correctly
tightened.
¾
Ensure that there are no additional areas of danger caused by interfaces to other components.
¾
Ensure that the wiring is in accordance with the specification and legal directives.
¾
Check all protection devices.
¾
Ensure that no personnel stand in hazardous areas near the conveyor.
Inspection before each commissioning
¾
Check the AdControl for visible damage.
¾
Check the DIP switch settings (see „DIP switches”, page 21).
¾
Check all protection devices.
¾
Clearly specify and monitor the way goods are placed on the conveyor.
¾
Ensure that the RollerDrive is not blocked.
¾
Ensure that no personnel stand in hazardous areas near the conveyor.
6.2
Operation
Caution
Accidental start-up of the RollerDrive!
Danger of crushing of limbs and damage to goods!
¾
Ensure that no unauthorised persons are near the conveyor before switching on the operating voltage.
Ambient conditions during operation see „Technical data”, page 18.
The AdControl starts transmitting the signals as soon as the voltage is switched on.