background image

"Cold Shot"

BOTTLE CAP ASSEMBLY

SUPPORT ASSEMBLY

RESERVE STRAINER

"Cold Shot"

10/03
Revised
9/5/04

1.75 Litre

750 ml

FLOW PLAN BOTTLE MOUNT 

 
Note:  Chill Shot should be positioned 
prior to the following being performed:  
  
1.  Remove cap from liquor bottle to be 

dispensed from Chill Shot.  

 
2.  Locate Bottle Cap Assembly and 

Sleeve.  750 ml bottle uses small 
sleeve, the 1.75 L bottle uses 
medium large sleeve. 

 
3. Install Sleeve on to Bottle Cap 

Assembly. 

 
4.  Install Bottle Cap Assembly with 

Sleeve onto the liquor bottle to be 
served. 

 
5.  Locate Reserve Strainer and place 

into the Bottle Reserve Assembly.   

 
6.  Carefully turn liquor bottle over and 

install into Chill Shot Bottle Reserve 
Assembly. 

 
7. Adjust the Support Assembly to 

balance the liquor bottle. 

 
8.  Repeat steps 1 through 7 for each 

bottle to be served. 

 
9. Plug unit into 110-volt outlet to 

engage the condensing unit and 
lights.  Immediately activate PUSH 
switch until a small amount of Tuaca 
is dispensed. 

 
10. Tuaca will be ready to dispense in 

approximately 15 minutes. 

 
 

 

 

 

 

11 

Summary of Contents for TUACA

Page 1: ...CI INTERNATIONAL CARBONIC INC 16630 Koala Rd Adelanto California 92301 800 854 1177 Installation and Service Manual 3 22 05 TUACA PUSH HERE...

Page 2: ...ling operating servicing and maintaining this equipment Refer to Table of Contents for page location of detailed information to answer questions that arise during installation operating service and ma...

Page 3: ...NSPECTION 8 SELECTING LOCATION 8 LOCATION RECOMMENDATIONS 8 ELECTRICAL REQUIREMENTS 8 TUACA UNIT INSTALLATION INSTRUCTIONS 9 FLOW PLAN BOTTLE MOUNT 11 CHAPTER III OPERATORS INSTRUCTIONS 12 DAILY PRE O...

Page 4: ...ater to 100 saturation We developed the first patented dispensing valve to dispense bulk beverage with carbonation equal to or in excess of bottled beverages A valve with three flavors and soda was an...

Page 5: ...nt of highly chilled 1oz servings of TUACA and lime Essentially the TUACA unit is designed to plug and play For proper function the TUACA unit must have 120 volt electrical supply and proper space aro...

Page 6: ...ill dispense a chilled shot below 32 degrees When the Push Switch is pushed the incoming TUACA is routed to a peristaltic pump and then through a cooling coil that is positioned next to the refrigerat...

Page 7: ...BY CHK BY APPR BY ICI CHILL SHOT TUACA GLW 58 57 59 60 51 45 44 46 47 41 42 43 14 8 4 7 9 27 10 28 29 30 31 40 36 34 32 56 50 52 53 55 62 63 65 64 66 67 61 35 26 8 8 48 33 37 38 49 5 1 2 3 6 39 8 11...

Page 8: ...AP BUSHING 14 8 S1335 TERMINAL SPACER 15 1 S1850 LED BRACKET 16 1 S1851 LOGO BRACKET 17 2 A0060 SCREW 6 32 X 1 4 FLAT HEAD 18 1 S1229 9 MERCHANDISER LIGHT BASE BACK 19 1 S0952 BALLAST 20 1 S0958 START...

Page 9: ...H PUMP HOUSING BODY PPM 48 1 S1741 CS PPM CONTROL 49 4 S1318 CUSHIONED FEET 50 1 S0276 A TRANSFORMER 51 1 S1837 CONTROL BOX 52 1 S1309 TERMINAL BOARD 53 1 S1840 CONTROL BOX COVER ONLY 54 1 S0766 ROCK...

Page 10: ...3 1 C S R M S 1 FAN MOTOR COMPRESSOR CONDENSING UNIT GROUND TERMINAL SCREW IN CONTROL BOX 110 VOLT LAMP LED LIQUOR MOTOR GREEN WHITE BLACK FO5 PP 1 2 3 4 5 6 6 6 5 5 5 4 4 4 3 3 3 2 2 2 1 1 1 6 A B C...

Page 11: ...TANT Ambient temperature for cooling unit should not exceed 100 degrees F Operation of cooling unit in ambient above 100 degrees F can and will contribute to early failure of condensing unit and poor...

Page 12: ...tely contact Sentry BevCon at 800 661 3003 Do not discard the shipping carton or any shipping materials in the event a freight claim must be filed 1 The following parts are included with this Shippmen...

Page 13: ...ling coils are filled Dispense 6 8 ounces in order to flush unit DO NOT REUSE 10 In approximately 15 minutes the unit will dispense ice cold TUACA shots 11 Your unit is equipped with an on off switch...

Page 14: ...l Sleeve on to Bottle Cap Assembly 4 Install Bottle Cap Assembly with Sleeve onto the liquor bottle to be served 5 Locate Reserve Strainer and place into the Bottle Reserve Assembly 6 Carefully turn l...

Page 15: ...clean This may be accomplished by one of three methods One method is use of a condenser brush a longhaired soft bristle brush to gently sweep fins of condenser clean Second method is to use a strong...

Page 16: ...odically To accomplish this task shut off the condensing unit at condensing unit on off switch located under the control box on the lower right hand side Flush all liquor out of liquor coil and into a...

Page 17: ...if dirty clean with soft bristle brush Clean exteriors of nozzle tubes with a soft clothe and warm water Replace valve nozzle then go to step 3 3 Fill bottle reserve with a caustic based low sudsing n...

Page 18: ...ance that must be performed A Yes again depending on usage your peristaltic pump tubing will have to be changed Q How often must this tubing be changed A Again depending on the usage approximately eve...

Page 19: ...motor or compressor terminals Fan blade obstructed Inoperative condenser fan motor 1 2 3 Tighten connections or replace cord Remove obstruction Replace condenser fan motor Compressor does not operate...

Page 20: ...______________________________ ____________________________ __________________________________ ____________________________ _____________________________________ __________________________________ ___...