Intermec EasyCoder ESim v4.20—Programmer’s Reference Manual
111
Chapter 7—Commands
US – Enable Error Reporting
Description
Th
is command is used to enable the printer’s status reporting
feature with optional direct recovery.
Syntax
US[A][B][E]
Parameters
A
If any error of type A occurs, it will be directly recovered and continue in normal
mode. No stop for recovery, often performed with FEED key.
B
If any error of type B occurs, it will be directly recovered and continue in normal
mode. No stop for recovery, often performed with FEED key.
E
Error 13 LTS reply control (label taken sensor). Returns error 13 if LTS detects a
label before and after printing.
Remarks
Any or all parameters can be activated at the same time. Refer to
Appendix A for information on error types.
Parameters are saved in the Flash memory.
Th
e format of the error messages is controlled by the
eR
com-
mand.
Example
Command
Reply
Comment
USABE
↵
<ACK>
Activate all error fl ags
eRQ,6,R
↵
(no reply)
Setup User-Defi ned Error/Status Character control to
Q for <XOFF> and <R> for <XON>
N
↵
(no reply)
Clear image buff er and errors
AA
↵
(no reply)
Erroneous command type A; Syntax error
P
↵
<NAK>01Q
Print image buff er with error 01
R
Direct recovery error 01 (type A) and continue
Summary of Contents for ESim v4.20
Page 1: ...Programmer s Reference Manual ESim v4 20 for EasyCoder C4 Bar Code Label Printer...
Page 14: ...8 Intermec EasyCoder ESim v4 20 Programmer s Reference Manual Chapter 1 General Information...
Page 136: ...130 Intermec EasyCoder ESim v4 20 Programmer s Reference Manual Chapter 8 Fonts...
Page 159: ......