IFS NS3502-8P-2S User Manual
326
1
Optional
0.44 to 3.84 Watts
Very low power
2
Optional
3.84 to 6.49 Watts
Low power
3
Optional 6.49 to 12.95 Watts (or to 15.4Watts)
Mid power
4
Optional
12.95 to 25.50 Watts (or to
30.8Watts)
High power
In this mode the
Maximum Power fields
have no effect.
Allocation mode
In this mode the user allocates the amount of power that each port may reserve. The
allocated/reserved power for each port/PD is specified in the Maximum Power fields. The ports
are shut down when total reserved powered exceeds the amount of power that the power supply
can deliver.
In this mode the port power is not turned on if the PD requests more power
the available.
Consumption mode
In this mode the ports are shut down when the actual power consumption for all ports exceeds
the amount of power that the power supply can deliver or if the actual power consumption for a
given port exceeds the reserved power for that port. The ports are shut down according to the
ports priority. If two ports have the same priority the port with the highest port number is shut
down.
Priority mode
In this mode the user assign the priority to the ports/PD. When the total PoE power consumption
request is over the allowed power supply limitation, the system shut down PoE ports by port
priority setting.