background image

SPECIFICATIONS 

 
 

 

 
 

OPERATING POWER   

 

12 VDC Regulated 
Supplied by NX8-E or NX-320 

 
 
OPERATING TEMPERATURE   

32 to 120 degrees F 

 
CURRENT DRAW 

 

 

110 mA Maximum 
75 mA without Sounder 

 
 
LCD KEYPAD DIMENSIONS 

 

6.4" Wide 
5.3" High 
1.0" Deep 

 
SHIPPING 

WEIGHT 

  2 

lbs. 

 
 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

CADDX CONTROLS, INC. 

1420 NORTH MAIN STREET 

GLADEWATER, TEXAS  75647 

TOLL FREE 800-727-2339 

FAX 903-845-6811 

www.caddx.com 

 

 

 
 

NX148-E INSTALLATION MANUAL 
NX148EIA00 

REV. A   (11-10-00) 

 

Summary of Contents for CADDX NX148-E

Page 1: ...5 SET KEYPAD OPTIONS 6 SET KEYPAD NUMBER AND PARTITION 7 KEYPAD FUNCTIONS 7 READING THE EVENT LOG 7 SET ELAPSED INCREMENTS SINCE LAST AUTOTEST 8 SET SYSTEM TIME AND DATE 8 ADJUST KEYPAD TONE 8 VIEW Z...

Page 2: ...the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on o...

Page 3: ...RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YARD BUTTON EXIT INFRARED NURSERY SHOP T...

Page 4: ...t to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrol...

Page 5: ...keypad numbers with r 9 4 prior to programming custom messages If a keypad is added after messages are programmed you should either program ALL messages in it or enter custom message programming on an...

Page 6: ...rt The current state of the option will be shown in the lower right corner of the display Press r to advance to the next option without making changes Otherwise follow the directions on the bottom lin...

Page 7: ...on September 25th at 5 27 p m by user 75 The r shows that this event is not programmed to be reported to the central monitoring station POSSIBLE LOG MESSAGES 7 DISPLAY DESCRIPTION TXlobat Transmitter...

Page 8: ...de Entry A code has been entered First Open First Open Reports when the first partition is disarmed Last Close Last Close Reports when the last partition is armed Sprnklr Sprinkler Instant sprinkler s...

Page 9: ...r 4 6 The LCD Screen will prompt to Select Light Number 0 9 2 Enter the number of the device to edit The LCD will display the light number on the left On the right side of the display it will prompt...

Page 10: ...X4 6 8 or 3 digit NX8E user number Remember to use leading zeros i e 03 or A003 for user 3 The LCD will now prompt you for the first in the following list of attributes PROMPTS 1 Outputs used Open Clo...

Page 11: ...y To set the multi partition mode use the r 9 3 function and answer YES to the question Master keypad NOTE r 1 followed by a code will temporarily access the Master Mode The keypad will revert back to...

Page 12: ...ash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the up scroll key To arm all of the areas pre...

Page 13: ...this display press r 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press Control Over Current A short circuit...

Page 14: ...an expansion device has been opened Expansion RF Jammed A radio receiver is being jammed Expansion Trouble An expansion device or keypad is not reporting to the control panel Expansion Siren trouble...

Page 15: ...225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 NX148 E MAXIMUM WIRE RUN Note These numbers are for one keypad at the...

Page 16: ...0 degrees F CURRENT DRAW 110 mA Maximum 75 mA without Sounder LCD KEYPAD DIMENSIONS 6 4 Wide 5 3 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS INC 1420 NORTH MAIN STREET GLADEWATER TEXAS 75647 TO...

Reviews: