7 RESET
FUNCTION
1) Disarm the system.
2) Enter [
r
]-[
7
]
The smoke detectors, zone troubles, and zone tampers have now
been reset.
If the keypad begins beeping, the reset did not execute properly. Enter your code to silence the keypad. Wait a
few minutes and repeat step 2 to attempt another reset.
r
9 8
Pressing [
r
]-[
9
]-[
8
] while the system is disarmed will cause the control to do a callback for a download.
NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [
r
]-[9]-[8] IF ENABLED IN LOCATION
41 OF THE CONTROL PANEL.
(Refer to the NX-4, -6, -8, -8E Installation Manual)
r
9 9
Pressing [
r
]-[
9
]-[
9
] while the system is disarmed will cause the control to seize the phone line for a
download.
NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [
r
]-[9]-[9] IF ENABLED IN
LOCATION 41 OF THE CONTROL PANEL. (Refer to the NX-4, -6, -8, -8E Installation Manual)
r
CHIME
If enabled in the control panel, entering [
r
]-[CHIME] followed by a user code will allow a walk-through
zone test where all zones become silent and local (non-reporting). Each time a zone is faulted, the
number of the faulted zone(s) will be displayed on the keypad and the chime will sound. It will also be
entered into alarm memory and the internal log. To exit at any time during this mode, enter a user
code. Otherwise, the
A
Walk-Test Mode
@
will automatically exit after 15 minutes.
PARTITIONED SYSTEMS OPERATION
The NX148-E can be programmed to operate all the system partitions simultaneously. To set the multi-partition mode,
use the
r
9 3
function, and answer "YES" to the question "Master keypad?".
NOTE:
[
r
]-[
1
] followed by a code will
temporarily
access the Master Mode. The keypad will revert back to its
assigned partition 60 seconds after a keypress or 10 seconds without a keypress. Press [
#
] to exit this mode.
LIGHTS IN PARTITIONING MASTER MODE
#
ARMED
will illuminate if ALL partitions are armed.
#
READY
will illuminate if ALL partitions are "Ready". The
ready light
will flash if all areas are Ready or Force
armable.
#
FIRE
will illuminate if ANY one area has a Fire condition. The
fire light
will flash if ANY area has a Fire Trouble
condition.
#
POWER
will illuminate if the primary power is connected to the NX8-E control panel. It will flash if the system
has a low standby battery condition.
#
STAY
will illuminate if ANY area has the
stay light
on.
#
CHIME
will illuminate if ANY partition is in the "Chime" mode
.
#
EXIT
will illuminate if ANY area is timing an exit delay. It will flash if ANY area is in the last 10 seconds of an
exit delay.
#
BYPASS
will illuminate if ANY area has a zone bypassed.
#
CANCEL
will flash during an abort delay time. If a code is entered followed by the [
CANCEL
] key while this light
is flashing, all abortable reports will stop the communication process to the central station. If a code is entered
followed by the [
CANCEL
] key during or after an alarm report, the
cancel light
will illuminate and remain
constant until the central station has received the cancel report.
#
SOUNDER
will sound if ANY area has the sounder on. This includes Entry delay, Exit delay, Chime, and Alarm.
11